2003
DOI: 10.1109/tuffc.2003.1235328
|View full text |Cite
|
Sign up to set email alerts
|

Single crystal PMN-0.33PT/epoxy 1-3 composites for ultrasonic transducer applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
70
0
2

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 128 publications
(73 citation statements)
references
References 11 publications
1
70
0
2
Order By: Relevance
“…[001] c Pb(Mg 1/3 Nb 2/3 )O 3 -xPbTiO 3 (PMN-xPT) single crystals with compositions close to morphotropic phase boundary (MPB) are well known as typical relaxor ferroelectrics with ultrahigh piezoelectric coefficient (d 33 > 2000 pC/N) and electromechanical coupling factor (k 33 > 0.9) [5], with various high-tech applications, such as sonar transducers, medical ultrasonic detectors, actuators, to name a few [6][7][8]. The thermal stability of dielectric and piezoelectric properties of PMN-xPT single crystals is very important for most electromechanical applications.…”
Section: Introductionmentioning
confidence: 99%
“…[001] c Pb(Mg 1/3 Nb 2/3 )O 3 -xPbTiO 3 (PMN-xPT) single crystals with compositions close to morphotropic phase boundary (MPB) are well known as typical relaxor ferroelectrics with ultrahigh piezoelectric coefficient (d 33 > 2000 pC/N) and electromechanical coupling factor (k 33 > 0.9) [5], with various high-tech applications, such as sonar transducers, medical ultrasonic detectors, actuators, to name a few [6][7][8]. The thermal stability of dielectric and piezoelectric properties of PMN-xPT single crystals is very important for most electromechanical applications.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4] Nevertheless, speeding up the poling process as well as enhancing the properties are still the challenges for manufacturers using the composites in production. It is generally believed that during the poling process, space charges in the polymer phase will drift and accumulate at the particle-matrix interfaces ͑this is the reason for the long poling time, e.g., 1 h or even longer͒.…”
Section: Introductionmentioning
confidence: 99%
“…For comparison, the commonly used piezoelectric ceramic lead zirconate titanate (PZT-5H) has a d 33 of ~ 600 pC/N and a k 33 of ~ 0.75. The PMN-PT single crystals have been shown to provide better sensitivity and bandwidth than PZT when used in medical imaging transducers [5][6]. However, there is little work reported on the study of their use in resonator applications.…”
Section: Introductionmentioning
confidence: 99%