2014
DOI: 10.1016/j.ultrasmedbio.2013.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Single-Particle Optical Sizing of Microbubbles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(26 citation statements)
references
References 29 publications
0
26
0
Order By: Relevance
“…19,20 Size distributions and concentrations of the probe-sonicated microbubbles were measured by electrical impedance sensing using the MultiSizer 3 (Beckman Coulter, Brea, CA), which was found to be more accurate than optical extinction. 21 For enhanced stability during condensation and re-vaporization, all experiments were done in C 4 F 10 (or C 3 F 8 ) saturated PBS solution. 20 This was accomplished by stirring and degassing PBS under house vacuum for 8 h and then repressurizing it by filling the head space with C 4 F 10 (or C 3 F 8 ) and stirring for 24 h, all at room temperature.…”
Section: Introductionmentioning
confidence: 99%
“…19,20 Size distributions and concentrations of the probe-sonicated microbubbles were measured by electrical impedance sensing using the MultiSizer 3 (Beckman Coulter, Brea, CA), which was found to be more accurate than optical extinction. 21 For enhanced stability during condensation and re-vaporization, all experiments were done in C 4 F 10 (or C 3 F 8 ) saturated PBS solution. 20 This was accomplished by stirring and degassing PBS under house vacuum for 8 h and then repressurizing it by filling the head space with C 4 F 10 (or C 3 F 8 ) and stirring for 24 h, all at room temperature.…”
Section: Introductionmentioning
confidence: 99%
“…They are widely used for dense multiphase flows in industrial processes and in microstructures as well, for example for biological cell counting and sizing [6][7][8][9][10][11]. In addition to complex and expensive equipments, the main disadvantage of these techniques is their dependence on the visibility of the measurement volume and on the focal distance.…”
Section: Introductionmentioning
confidence: 99%
“…Microbubbles with DFB gas cores and phospholipid shells formed spontaneously when agitated in a Vialmix device (Lantheus Medical Imaging, N. Billerica, MA). The concentration, and diameter of microbubbles in this emulsion was measured via (single particle) optical techniques (Accusizer 780, Particle Sizing Systems, Santa Barbara, CA, USA) (Satinover et al 2014). For targeted bubbles, a biotinylated PEG was used (DSPE-PEG2000-Biotin) (Zhao et al 2004) to replace 50% of the DSPE-PEG2000.…”
Section: Methodsmentioning
confidence: 99%