2012
DOI: 10.1161/circep.111.970293
|View full text |Cite
|
Sign up to set email alerts
|

Single-Ring Posterior Left Atrial (Box) Isolation Results in a Different Mode of Recurrence Compared With Wide Antral Pulmonary Vein Isolation on Long-Term Follow-Up

Abstract: Additional linear ablations have been added to WAI in an attempt to improve efficacy, in particular at the left mitral isthmus and left atrial roof. [7][8][9] However, linear ablation can be technically demanding, and conduction recovery across these additional ablation lines is common and associated with recurrences, especially of macroreentrant atrial tachyarrhythmias. 10 Wider isolation techniques are associated with a high incidence of organized atrial © 2012 American Heart Association, Inc. Background-Ele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
59
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 76 publications
(64 citation statements)
references
References 32 publications
1
59
0
Order By: Relevance
“…Fifteen studies [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] meeting the prespecified inclusion criteria, and 11 long-term (≥2 years) AFCA studies, [22][23][24][25][26][27][28][29][30][31][32] for which the corresponding author was contacted and agreed to participate, were eventually included. First author, study design, publication date, and main characteristics of each included study are reported in Table 1 in the Data Supplement (Material in the Data Supplement).…”
Section: Resultsmentioning
confidence: 99%
“…Fifteen studies [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] meeting the prespecified inclusion criteria, and 11 long-term (≥2 years) AFCA studies, [22][23][24][25][26][27][28][29][30][31][32] for which the corresponding author was contacted and agreed to participate, were eventually included. First author, study design, publication date, and main characteristics of each included study are reported in Table 1 in the Data Supplement (Material in the Data Supplement).…”
Section: Resultsmentioning
confidence: 99%
“…13 Patients were reviewed at 3, 6, and 12 months and then every 6 months thereafter. At 6 months, follow-up patients had a 7-day Holter monitor recording as a mean of documenting recurrent arrhythmias.…”
Section: Patientsmentioning
confidence: 99%
“…4 A recent meta-analysis observed that wide area pulmonary vein isolation is more favorable in paroxysmal and persistent AF. 21 Substrate dependent factors extraneous to the pulmonary veins have been implicated in permanent AF.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…4 The study was approved by the Sydney West Area Health Service Human Research Ethics Committee and conforms with the ethical guidelines of the 1975 Declaration of Helsinki.…”
mentioning
confidence: 99%