EUROCON 2007 - The International Conference on "Computer as a Tool" 2007
DOI: 10.1109/eurcon.2007.4400254
|View full text |Cite
|
Sign up to set email alerts
|

Sliding mode control of a single-phase series active power filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 10 publications
0
9
0
Order By: Relevance
“…The PID and the cascade controllers exhibit accurate performance; however, when there was no load connected downstream the DVR, only the SF controller was able to properly damp the LC filter resonance. Control alternatives like hysteresis controllers can be found in the literature [23,24], and a comparative analysis with this alternative is of interest for further research. All the control system developments were validated in a 5 kVA prototype of a DVR, with accurate results.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The PID and the cascade controllers exhibit accurate performance; however, when there was no load connected downstream the DVR, only the SF controller was able to properly damp the LC filter resonance. Control alternatives like hysteresis controllers can be found in the literature [23,24], and a comparative analysis with this alternative is of interest for further research. All the control system developments were validated in a 5 kVA prototype of a DVR, with accurate results.…”
Section: Discussionmentioning
confidence: 99%
“…However, a Posicast controller leads to poor results when the system dynamics are not accurately known. Alternatively, Petkova et al [23] and Antchev et al [24] presented a fast sliding-mode controller for a series active power filter (SAPF) that protected a load against voltage harmonics. The main advantage of this controller was robustness against variations in the system parameters, and this feature is of interest for its application to a DVR.…”
Section: Introductionmentioning
confidence: 99%
“…Usually pulse-width modulation is used to control the filters, but also researches of sliding mode control of the filters on several variables are known (Cardenas et al, 1999;Hernandez et al, 1998). In this sub-chart sliding mode control of a single-phase series active power filter on one variable -the supply voltage of the load is studied (Antchev et al, 2007;Antchev et al, 2008). …”
Section: Experimental Studymentioning
confidence: 99%
“…In such a way, the system of APF's does not consume any active power from the AC grid, its supply being provided by the renewable energy source. a) Series APF Its control system is synchronized with the voltage of the public distribution grid; it tracks continuously the instantaneous values of the local-grid voltage U L , and compares them to those of a reference sinusoid of fixed value [6]. Switching over the filter devices is performed in such a way that at any time the voltage U F complements the instantaneous values of the voltage U S from the public distribution grid to those of the reference sinusoidal voltage.…”
Section: B Concept Of Active Power Filters (Tu Sofia)mentioning
confidence: 99%