2008
DOI: 10.1016/j.jhazmat.2007.05.033
|View full text |Cite
|
Sign up to set email alerts
|

Slurry analysis after lead collection on a sorbent and its determination by electrothermal atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…Use of low concentrations of HNO 3 and H 2 O 2 or other reagents that enhance the decomposition of carbonaceous residues inside the atomizer which can reduce detection power [93]. Under optimum conditions, results are frequently comparable to those obtained with acid digestion methods and total analyte recovery is achieved [28,29,70,[77][78][79][80][81][82]84,[87][88][89][90][91][92][93][94][95][96][97]. Despite optimization, incomplete liberation of the analyte from the sample matrix is not always achieved, leading to unsatisfactory results [35,85,86].…”
Section: Slurrymentioning
confidence: 99%
See 2 more Smart Citations
“…Use of low concentrations of HNO 3 and H 2 O 2 or other reagents that enhance the decomposition of carbonaceous residues inside the atomizer which can reduce detection power [93]. Under optimum conditions, results are frequently comparable to those obtained with acid digestion methods and total analyte recovery is achieved [28,29,70,[77][78][79][80][81][82]84,[87][88][89][90][91][92][93][94][95][96][97]. Despite optimization, incomplete liberation of the analyte from the sample matrix is not always achieved, leading to unsatisfactory results [35,85,86].…”
Section: Slurrymentioning
confidence: 99%
“…Temperatures most widely employed for atomization of Cd are 1100-2050°C, i.e., 1100 [80], 1200°C [46,86,96], 1300°C [83,89,92], 1400°C [41], 1500°C [7,93,94], 1600°C [27,67,70], 1650°C [10,53,54], 1700°C [31,50,81,97], 1800°C [34,36,43], 1900°C [1,17,44,72] and 2100°C [99]. For Pb, they are 1500-2200°C, i.e., 1500°C [80,94], 1600°C [27,70,83,92], 1650°C [106] 1700°C [81,89,97,107], 1800°C [4,7,10,36,41,53,54,67,95,96,…”
Section: Modifier Use and Chemical Vapor Generationmentioning
confidence: 99%
See 1 more Smart Citation
“…In current regulations of United States, most color additives approved for cosmetic use could to contain up to 20 mg Pb=g (Code of Federal Regulations 2008) and it is expected that the lead concentration in cosmetics is much lower. Lead is one of the most common contaminants in the environment and is considered to be a toxic element in humans and animals that does not have any physiological functions in organisms (Baysal et al 2008). The toxicity of Pb at high levels of exposure is well known, but continual exposure to relatively low levels of lead may entail adverse health effects.…”
Section: Introductionmentioning
confidence: 99%
“…A suspension of fine particles holding the analyte was also introduced directly into a graphite tube for determining the desired element; high enrichment factors were observed in the slurry injection techniques. [32][33][34][35][36] Although the coupling of flow-injection on-line column preconcentration/separation techniques to ETAAS is effective for the simplifying the operation, 21 the treatment of large volumes of aqueous samples is often time-consuming. These methods are unsuitable for processing many samples in a short time.…”
Section: Introductionmentioning
confidence: 99%