2008
DOI: 10.2175/106143008x266805
|View full text |Cite
|
Sign up to set email alerts
|

Solid‐Phase Extraction and Preconcentration of Copper in Mineral Waters with 4‐(2‐Pyridyl‐Azo) Resorcinol‐Loaded Amberlite XAD‐7 and Flame Atomic Absorption Spectrometry

Abstract: A simple, sensitive, accurate, and selective method for determination of ultratrace levels of copper is modified. The method is based on preconcentration of copper on the 4-(2-pyridyl-azo) resorcinol-loaded amberlite XAD-7 (non-ionic copoly[styrene-acrylic compound]) at pH 5.0 to 6.5 for contact time as low as 45 minutes. The adsorbed copper was eluted with concentrated nitric acid and measured by flame atomic absorption spectrometry. Recoveries of up to 90% were achieved. The optimized preconcentration method… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 30 publications
0
9
0
Order By: Relevance
“…The small volume of the surfactant-rich phase (0.5 mL), permitting a design for extraction strategy, having lower toxicity than those using organic solvents. The proposed method shows very good sensitivity and precision and has some good advantages over other preconcentration methods reported in the literature [42][43][44][45][46][47][48][49][50][51][52].…”
Section: Resultsmentioning
confidence: 99%
“…The small volume of the surfactant-rich phase (0.5 mL), permitting a design for extraction strategy, having lower toxicity than those using organic solvents. The proposed method shows very good sensitivity and precision and has some good advantages over other preconcentration methods reported in the literature [42][43][44][45][46][47][48][49][50][51][52].…”
Section: Resultsmentioning
confidence: 99%
“…The performance characteristics of the proposed method and other selected SPE/FAAS systems for comparative purposes in the literature are given in Table 5. The proposed procedure shows good detection limits and precision with reasonable eluent volume, flow rate and preconcentration factor over other SPE off-line preconcentration methods [39][40][41][42][43][44][45][46]. The method is simple, accurate can be applied for the determination of analytes in environmental samples [39][40][41][42][43][44][45][46][47].…”
Section: Resultsmentioning
confidence: 99%
“…The volume of aqueous solution is a critical and important factor in the solid phase extraction of the metal ions to obtain high preconcentration factor [47][48][49][50][51][52][53]. The influences of sample volume on the recoveries of copper (II) ions on carbon nanotube were investigated in the range of 50-750 mL.…”
Section: Effect Of Sample Volumementioning
confidence: 99%