2009
DOI: 10.1016/j.jhazmat.2008.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Solid phase extraction of lead and cadmium using solid sulfur as a new metal extractor prior to determination by flame atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
48
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 157 publications
(48 citation statements)
references
References 29 publications
0
48
0
Order By: Relevance
“…The equilibrium data of Cd (II) and Pb (II) ions adsorption onto Amberlite XAD-8 resin were obtained with the Langmuir isotherm equation and the adsorption capacity of the Amberlite XAD-8 resin, without any lost of its physical-chemical features and adsorption properties, were evaluated as 3.76 mg g -1 and 5.07 mg g -1 , respectively. The data obtained from the proposed method have been also compared with the previously reported SPE methods [31][32][33][34][35][36] in terms of some optimization parameters ( Table 6). The distinguished features of the present work are that the RSD and LOD values are relatively low, the working pH near to neutral and the preconcentration factor is relatively high when compared to other methods.…”
Section: Discussionmentioning
confidence: 99%
“…The equilibrium data of Cd (II) and Pb (II) ions adsorption onto Amberlite XAD-8 resin were obtained with the Langmuir isotherm equation and the adsorption capacity of the Amberlite XAD-8 resin, without any lost of its physical-chemical features and adsorption properties, were evaluated as 3.76 mg g -1 and 5.07 mg g -1 , respectively. The data obtained from the proposed method have been also compared with the previously reported SPE methods [31][32][33][34][35][36] in terms of some optimization parameters ( Table 6). The distinguished features of the present work are that the RSD and LOD values are relatively low, the working pH near to neutral and the preconcentration factor is relatively high when compared to other methods.…”
Section: Discussionmentioning
confidence: 99%
“…A comparison of the extraction procedure with the other reported preconcentration methods [30][31][32][33][34][35] for zinc and cadmium ions are given in Table 8. Some parameters obtained were comparable to those presented by other methods described in the literature.…”
Section: Comparison With Other Methodsmentioning
confidence: 99%
“…(2) Optimum volume of the eluting solution and low consumption of chemical reagents obtained by using the present methodology permitted to design an extraction strategy that posses one of the following advantages presenting robustness, low cost, low detection limits and good S.D.s, good extraction efficiency and lower toxicity than those previously reported in literature. [39][40][41][42][43][44][45][46][47] …”
Section: Applicationsmentioning
confidence: 99%