2016
DOI: 10.1088/2058-8585/1/4/043001
|View full text |Cite
|
Sign up to set email alerts
|

Solution-processed image sensors on flexible substrates

Abstract: Copper(I) thiocyanate (CuSCN) as a hole-transport material for large-area opto/electronics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
41
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 46 publications
(41 citation statements)
references
References 110 publications
0
41
0
Order By: Relevance
“…[ 35,36 ] The broad LDR is particularly important for image sensors, which means that the device can operate over a broad light intensity range. [ 37 ] The spectral responsivity ( R ) and specific detectivity ( D *) are other two key figure‐of‐merit parameters of photodetectors. The R and D * are expressed as: [ 38 ] R = JphJdarkLlight D*=A f0.5in/R where A, f , and i n are the effective area of the device, the electrical bandwidth, and the noise current, respectively.…”
Section: Figurementioning
confidence: 99%
“…[ 35,36 ] The broad LDR is particularly important for image sensors, which means that the device can operate over a broad light intensity range. [ 37 ] The spectral responsivity ( R ) and specific detectivity ( D *) are other two key figure‐of‐merit parameters of photodetectors. The R and D * are expressed as: [ 38 ] R = JphJdarkLlight D*=A f0.5in/R where A, f , and i n are the effective area of the device, the electrical bandwidth, and the noise current, respectively.…”
Section: Figurementioning
confidence: 99%
“…Comparing pressure signals from arterial pulses and electrocardiograms (ECGs) enable extraction of pulse transit times to determine the systolic blood pressure . Alternatively, the blood flow motion during heart beats can be monitored indirectly in photoplethysmograms (PPGs) which use flexible photodetector technologies . Notably, a complete epidermal system that allows wireless, battery‐free, continuous sensing of PPGs and ECGs on neonates has been achieved with performance comparable to clinical‐grade monitoring systems (Figure b) .…”
Section: Applications Of Pressure Sensors In Monitoring Body Motionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9][10][11][12][13] Especially, optical imaging is important for proximity sensing, [14] sensing of activities of blood vessels, [15] body skeleton diagnosis using X-rays, [16,17] and retinal reconstruction. [16,17,[31][32][33][34][35] With advances of these transistors, organic image sensors with a large numbers of pixels (e.g., 256 × 256) have been demonstrated. [21][22][23][24][25][26][27][28][29][30] To realize a multiplexing signal readout for organic photodiodes, transistors-which are three-terminal devices-have been commonly used.…”
Section: Doi: 101002/aelm201800311mentioning
confidence: 99%