2018
DOI: 10.1364/oe.26.004479
|View full text |Cite
|
Sign up to set email alerts
|

Spatial coherence measurement and partially coherent diffractive imaging using self-referencing holography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 30 publications
(13 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…To verify the CSD distribution and measure the coherence singularities of the PC-PEPV beam, the other path is transmitted through the beam splitter and focused onto SLM 2 . The phase written into SLM 2 is shown in Figure 3B, containing a central square window with displacement grating, spherical wave phase for focusing, and an additional central phase perturbation [51,52]. Note that the focused input PC-PEPV beam and the center of SLM 2 need to be aligned.…”
Section: Methodsmentioning
confidence: 99%
“…To verify the CSD distribution and measure the coherence singularities of the PC-PEPV beam, the other path is transmitted through the beam splitter and focused onto SLM 2 . The phase written into SLM 2 is shown in Figure 3B, containing a central square window with displacement grating, spherical wave phase for focusing, and an additional central phase perturbation [51,52]. Note that the focused input PC-PEPV beam and the center of SLM 2 need to be aligned.…”
Section: Methodsmentioning
confidence: 99%
“…Each singleparticle interference image therefore represents the in-line hologram of the corresponding scattering particle. The self-referencing scheme is strongly reminiscent of in-line Gabor holography [84,[89][90][91], originally proposed as a way to improve the resolution of the Transmission Electron Microscope (TEM) [92] and nowadays largely exploited in the visible range with laser light [93][94][95][96] or in the X-ray domain with coherent FEL beams [97][98][99][100][101][102][103][104]. The same self-referencing scheme is also at the basis of the Point Diffraction Interferometer (PDI) used in the X-ray community for phase-contrast imaging and wavefront characterization [99,[105][106][107][108][109].…”
Section: On the Origin Of Heterodyne Specklesmentioning
confidence: 99%
“…The corresponding correlation function can be measured with the help of self-referencing holography, as mentioned in Ref. [47], in which the correlation function of the illumination source can be retrieved. Figure 10 shows our experimental results in relation to the intensity of a focused HGCSMLG 0l beam at different distances for different beam orders m, n with l = 2.…”
Section: Experimental Verificationmentioning
confidence: 99%
“…The corresponding correlation function can be measured with the help of self-referencing holography, as mentioned in Ref. [47], in which the correlation function of the illumination source can be retrieved. The intensity distribution morphs from a donut shape into an array form on propagation, which agrees well with Figure 3.…”
Section: Experimental Verificationmentioning
confidence: 99%