2021
DOI: 10.1038/s41598-021-82846-5
|View full text |Cite
|
Sign up to set email alerts
|

Speciation and milk adulteration analysis by rapid ambient liquid MALDI mass spectrometry profiling using machine learning

Abstract: Growing interest in food quality and traceability by regulators as well as consumers demands advances in more rapid, versatile and cost-effective analytical methods. Milk, as most food matrices, is a heterogeneous mixture composed of metabolites, lipids and proteins. One of the major challenges is to have simultaneous, quantitative detection (profiling) of this panel of biomolecules to gather valuable information for assessing food quality, traceability and safety. Here, for milk analysis, atmospheric pressure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 23 publications
0
21
0
Order By: Relevance
“…Positive ions were recorded over an m/z range of 100-2000. External TOF calibration was performed manually by AP-LDI MS as previously described, 23 using sodium iodide, an acquisition time of 3 min with an m/z range of 100-2000 and Intellistart soware (MassLynx™; Waters). All samples were analysed with an acquisition time of 1 min.…”
Section: Lap-maldi Ms Analysismentioning
confidence: 99%
“…Positive ions were recorded over an m/z range of 100-2000. External TOF calibration was performed manually by AP-LDI MS as previously described, 23 using sodium iodide, an acquisition time of 3 min with an m/z range of 100-2000 and Intellistart soware (MassLynx™; Waters). All samples were analysed with an acquisition time of 1 min.…”
Section: Lap-maldi Ms Analysismentioning
confidence: 99%
“…https://dx.doi.org/10.22161/ijeab.74. 17 157 temperature in air. Then, free electrons from tin oxide are influenced by the oxygen, thus arresting the current flow.…”
Section: Gas Sensormentioning
confidence: 99%
“…https://dx.doi.org/10.22161/ijeab.74. 17 155 change in resistance produced by the fat content in milk.…”
Section: Introductionmentioning
confidence: 99%
“…Innovation in new ionisation sources, and the ongoing development of existing technologies provide ever more possibilities for the identification of milk fraud. Matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI–TOF MS) has been adapted to profile differences in milk chemical compounds from different mammalian species 34 36 and for the discrimination of plant-based milk from cow milk. However, sample pre-treatment and MALDI matrix chromophore preparation procedures are complex, which is an issue when attempting to develop rapid MALDI screening workflows.…”
Section: Introductionmentioning
confidence: 99%