2000
DOI: 10.1039/a909590j
|View full text |Cite
|
Sign up to set email alerts
|

Speciation of inorganic selenium in environmental matrices by flow injection analysis-hydride generation-atomic fluorescence spectrometry. Comparison of off-line, pseudo on-line and on-line extraction and reduction methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 47 publications
(19 citation statements)
references
References 21 publications
0
19
0
Order By: Relevance
“…Se concentrations in brains obtained from chickens were measured using the hydride generation-atomic fluorescence spectrometer (AFS-3200; Yongtuo Instruments) against the standard reference of Se (GBW(E)080441, National Research Center for Certified Reference Materials) [22]. Briefly, brain tissues were homogenized on ice in physiological saline and centrifuged at 1000×g and supernatants were collected for GPx, CAT, and MDA activity analysis using kits provided by Jiancheng Biotechnology Research Institute (Nanjing, China).…”
Section: Biochemical Assaysmentioning
confidence: 99%
“…Se concentrations in brains obtained from chickens were measured using the hydride generation-atomic fluorescence spectrometer (AFS-3200; Yongtuo Instruments) against the standard reference of Se (GBW(E)080441, National Research Center for Certified Reference Materials) [22]. Briefly, brain tissues were homogenized on ice in physiological saline and centrifuged at 1000×g and supernatants were collected for GPx, CAT, and MDA activity analysis using kits provided by Jiancheng Biotechnology Research Institute (Nanjing, China).…”
Section: Biochemical Assaysmentioning
confidence: 99%
“…For real samples selenium was determined from slurry prepared as described previously [31]. The procedure for determining the amount of Se(IV) needs to switch off the coupled microwave oven in order to avoid the reduction of species.…”
Section: Operating Conditions For Volatile Generation-detectionmentioning
confidence: 99%
“…The hydrogen obtained from the volatile generation reaction and an auxiliary hydrogen flow sustained the diffusion flame in the atomisation cell. Signals were recorded using a Waters 746 integrator (Millipore, Bedford, MA, USA) and subsequently processed [31].…”
Section: Hg-aas; Hg-afs; Hg-icp-msmentioning
confidence: 99%
“…As noted above, selenium species must be reduced to the Se(IV) state prior to the hydride generation stage. The reduction of Se(VI) to Se(IV) by hydrochloric acid in a flow-injection manifold has been reported [20][21][22]. For organo-selenium compounds an oxidation step is required to covert the selenium to selenium (VI) prior to reduction.…”
Section: Introductionmentioning
confidence: 99%