2012
DOI: 10.1016/j.talanta.2012.02.056
|View full text |Cite
|
Sign up to set email alerts
|

Specific and targeted detection of viable Escherichia coli O157:H7 using a sensitive and reusable impedance biosensor with dose and time response studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
27
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(30 citation statements)
references
References 35 publications
1
27
0
Order By: Relevance
“…The LoD was found to be as low as 3.5·10 1 CFU· mL -1 , which is comparable with or better than other detection limit values previously reported for direct label-free bacterial detection (Basu et al, 2014;Dweik et al, 2012;EscamillaGómez et al, 2009;Li et al, 2014;Silva et al, 2014;Varshney and Li, 2007).…”
Section: Sensitivity Of the System In Kcl Solutionsupporting
confidence: 85%
“…The LoD was found to be as low as 3.5·10 1 CFU· mL -1 , which is comparable with or better than other detection limit values previously reported for direct label-free bacterial detection (Basu et al, 2014;Dweik et al, 2012;EscamillaGómez et al, 2009;Li et al, 2014;Silva et al, 2014;Varshney and Li, 2007).…”
Section: Sensitivity Of the System In Kcl Solutionsupporting
confidence: 85%
“…Ruminants, especially bovines, are the principal reservoir of STEC, and human contamination is often associated with consumption ground beef and direct contact with the animals or their environment (Savoye et al, 2011) STEC strains are highly pathogenic to human in low infectious doses, causing food-borne diseases through consumption of contaminated water or food (Dweik et al, 2012). Bovine milk and other dairy products such as yogurt and cheese have been associated with diseases caused by STEC (Chapman et al, 1993;Prandel et al, 2008;Martin & Beutin, 2011).…”
Section: Introductionmentioning
confidence: 99%
“…9. At low frequency (<1 MHz), the Cdi acting as an open circuit (Dweik et al 2012), so the function of impedance (Z) can be expressed as following (5):…”
Section: Debugging Working Parameters and Optimization Of The Self-asmentioning
confidence: 99%
“…He et al (He et al 2013) used electrophoresis technology on a microfluidic chip to enrich for bacteria, realizing the effective real-time on-line detection of Salmonella typhimurium. Interdigital microelectrodes have routinely been used for dielectrophoresis enrichment and impedance detection on microfluidic chips (Dweik et al 2012). Their advantages include sensitive signal responses, rapid achievement of stable state and a large detection area that could improve detection sensitivity.…”
Section: Introductionmentioning
confidence: 99%