Spectral Accuracy and Sulfur Counting Capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for Small Molecule Analysis

Abstract: Color Index Disperse Yellow 42 (DY42), a high-volume disperse dye for polyester, was used to compare the capabilities of the LTQ-Orbitrap XL and the LTQ-FT-ICR with respect to mass measurement accuracy (MMA), spectral accuracy, and sulfur counting. The results of this research will be used in the construction of a dye database for forensic purposes; the additional spectral information will increase the confidence in the identification of unknown dyes found in fibers at crime scenes. Initial LTQ-Orbitrap XL dat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
49
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 48 publications
(50 citation statements)
references
References 20 publications
1
49
0
Order By: Relevance
“…Unique ions must be present in >80% of interrogated region with respect to a reference region, and have an average abundance ratio greater than 2. The generated peak lists were searched against databases such as METLIN 53 and LIPID MAPS 54 , and putative compound identification was made possible by using the accurate mass in tandem with fundamental mass spectrometry concepts such as spectral accuracy 55,56 and sulfur counting. 57,58 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Unique ions must be present in >80% of interrogated region with respect to a reference region, and have an average abundance ratio greater than 2. The generated peak lists were searched against databases such as METLIN 53 and LIPID MAPS 54 , and putative compound identification was made possible by using the accurate mass in tandem with fundamental mass spectrometry concepts such as spectral accuracy 55,56 and sulfur counting. 57,58 …”
Section: Methodsmentioning
confidence: 99%
“…53 B) Confident identification of analyte by utilizing concepts such as spectral accuracy 55,56 and sulfur counting 57,58 in tandem with accurate mass to confidently identify an analyte observed in tissue.…”
Section: Figurementioning
confidence: 99%
“…2D). The molecular ion mass of compound A was m/z 340.1679 [MϩH] ϩ , which was in line with the protonated derivative of buprofezindihydrodiol (C 16 Generally, a mass error between Ϫ5 ppm and 5 ppm is acceptable (23), so the following upstream buprofezin catabolic pathway was proposed (Fig. 1A): the benzene ring of buprofezin was initially dihydroxylated into buprofezindihydrodiol, which was subsequently dehydrogenated to generate dihydroxybuprofezin.…”
Section: Resultsmentioning
confidence: 78%
“…22 Sulfur counting was carried out by comparing the relative abundance of the sulfur peak to the monoisotopic peak and multiplying by the ratio of the isotopic distributions for 32 S and 34 S ( 32 S: 34 S), Equation 1 (adapted from equation 3 in reference 23). A+2 Experimental is the experimental peak intensity of the 34 S peak and A Experimental is the experimental peak intensity of the monoisotopic peak.…”
Section: Methodsmentioning
confidence: 99%