2012
DOI: 10.1016/j.jmr.2012.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Spectral spatial electron paramagnetic resonance imaging as a tool to study photoactive dimethacrylate-based dental resins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 43 publications
0
5
0
Order By: Relevance
“…It means that if the spin probe administration is disturbed, it will be visible in the spatial image. Therefore, for precise localization of the tissue boundaries, EPRI should be supported by other anatomical imaging techniques such as MRI, 19 CT, 52 or US. 53 Although the anatomical resolution of EPRI is far from the techniques mentioned above, the development of a new spin probe with a narrow EPR linewidth will improve the spatial resolution and provide more details of the spin probe biodistribution.…”
Section: ■ Discussionmentioning
confidence: 99%
“…It means that if the spin probe administration is disturbed, it will be visible in the spatial image. Therefore, for precise localization of the tissue boundaries, EPRI should be supported by other anatomical imaging techniques such as MRI, 19 CT, 52 or US. 53 Although the anatomical resolution of EPRI is far from the techniques mentioned above, the development of a new spin probe with a narrow EPR linewidth will improve the spatial resolution and provide more details of the spin probe biodistribution.…”
Section: ■ Discussionmentioning
confidence: 99%
“…In addition, other characteristics of the material may have contributed to these results, such as the organic matrix composition, as the polymerization level varies according to the amount of the monomer present in the composite resins (20) . The increase in time of cure of Flash max p3 and Wood pecker from 10 seconds to 20 seconds gives higher microhardness values and greater depth of cure for all types of bulkfill composites while the high intensity with short curing time (Flash max p3 for 3 seconds) revealed lowest microhardness value in comparison to other groups of light curing protocol.…”
Section: Discussionmentioning
confidence: 99%
“…However, the most commonly used nitroxyl spin probes have a much larger linewidth (Δ H ∼ 1 G). Furthermore, since finite limits exist on the maximum G x that can be applied, Δ x cannot be reduced for unlabeled nitroxyls by simply increasing G x . , Even, the use of Fourier transform (FT)-based methods has not been helpful for the unlabeled nitroxides due to their short spin–spin relaxation time, T 2e . Hence, isotopically labeled ( 15 N, 2 D)-nitroxyls are preferred, , which makes the whole experiment quite expensive and synthetically demanding.…”
Section: Introductionmentioning