2022
DOI: 10.1016/j.jchromb.2022.123380
|View full text |Cite
|
Sign up to set email alerts
|

Spectrum-effect relationship between HPLC fingerprint and antioxidant of “San-Bai Decoction” extracts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…Since the correlation values of P7, P8, P4, P5 and P10 were all greater than 0.8, it can be inferred that the active ingredients represented by these 5 common peaks could have a stronger relevance with the TYR inhibition effect. By comparison, the correlation value of peak 6 was less than 0.6, indicating a weak relevance with the TYR inhibition effect [ 22 ]. As seen in Table 3 , the correlation from high to low was P7 > P8 > P4 > P5 > P10 > P2 > P11 > P9 > P1 > P3 > P6.…”
Section: Resultsmentioning
confidence: 99%
“…Since the correlation values of P7, P8, P4, P5 and P10 were all greater than 0.8, it can be inferred that the active ingredients represented by these 5 common peaks could have a stronger relevance with the TYR inhibition effect. By comparison, the correlation value of peak 6 was less than 0.6, indicating a weak relevance with the TYR inhibition effect [ 22 ]. As seen in Table 3 , the correlation from high to low was P7 > P8 > P4 > P5 > P10 > P2 > P11 > P9 > P1 > P3 > P6.…”
Section: Resultsmentioning
confidence: 99%
“…Fourteen batches of I. ilicifolia samples (S1–S14) were subjected to HPLC analyses under optimized conditions to give the corresponding chromatograms, which were then loaded into “Chromatographic Fingerprint Evaluation System for Traditional Chinese Medicine (2012 version)”, software recommended by the National Administration of China (Xiao, Shan, et al, 2022). With the HPLC chromatogram of sample S1 set as the reference fingerprint, the fingerprints of the remaining samples S2–S14 were automatically matched via the median multipoint correction method, generating the control fingerprint with 17 common chromatographic peaks.…”
Section: Methodsmentioning
confidence: 99%
“…The whole process was performed based on Microsoft Excel software with resolution coefficient set as 0.5. Xiao, Shan, et al (2022).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experiment was performed according to the procedure described by Xiao et al (2022) . Briefly, 2 mL of the DPPH free radical solution (0.04 g/L in 75% methanol) and 2 mL of the blank solvent were mixed in the test tube, and allowed to react in the dark for 30 min.…”
Section: Methodsmentioning
confidence: 99%