2020
DOI: 10.31285/agro.24.149
|View full text |Cite
|
Sign up to set email alerts
|

Spray nozzle performance on wheat

Abstract: Spray nozzle performance on wheat Desempeño de diferentes boquillas de pulverización sobre el cultivo de trigo Desempenho de diferentes pontas de pulverização na cultura do trigo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 12 publications
0
1
0
1
Order By: Relevance
“…The flat fan nozzle with air induction yielded 81.4 droplets cm −2 . This can be explained by the findings of Mur et al [ 42 ] that smaller droplets are more likely to be deposited on the target than droplets of the same volume distributed in larger droplets. Considering the indications of Syngenta Crop Protection AG (Basel, Switzerland), which recommends at least 30–40 droplets cm −2 for postemergence herbicide applications [ 43 ] and evaluating only the density found for the different nozzles in this study, both have the potential to facilitate efficiency in weed control.…”
Section: Resultsmentioning
confidence: 99%
“…The flat fan nozzle with air induction yielded 81.4 droplets cm −2 . This can be explained by the findings of Mur et al [ 42 ] that smaller droplets are more likely to be deposited on the target than droplets of the same volume distributed in larger droplets. Considering the indications of Syngenta Crop Protection AG (Basel, Switzerland), which recommends at least 30–40 droplets cm −2 for postemergence herbicide applications [ 43 ] and evaluating only the density found for the different nozzles in this study, both have the potential to facilitate efficiency in weed control.…”
Section: Resultsmentioning
confidence: 99%
“…For the nozzles used in the applications, the XR 11001 nozzle stood out with 137.44 droplets cm -2 , while the AirMix 11001 flat fan nozzle with air induction showed a density of 62.13 droplets cm -2 . Mur et al (2018), testing applications with different nozzles in soybean (Glycine max (L.) Merrill), also observed a lower droplet density for the AI 110015 air induction nozzle (Hypro ® , Cambridge, England) on the upper part of the crop. As will be seen later, the AirMix 11001 nozzle produced bigger droplets than the XR 11001 nozzle, which may explain the lower droplet density for this nozzle.…”
Section: Droplet Spectrummentioning
confidence: 95%
“…No caso do DMV, verificou-se que os resultados da aplicação desses tratamentos foram concordantes com maiores estimativas para esta variável nas parcelas aplicadas com esta classe de gota.No que diz respeito aos tratamentos com gotas finas, estes foram mais facilmente refletidos nas variáveis de deposição de calda, cobertura e densidade de gotas por estarem plotados no mesmo plano (Figura 7). Porém estas respostas dependem também de outros fatores como arquitetura da planta e IAF(LIAO et al, 2020) e condições meteorológicas adequadas(MUR et al, 2020).…”
unclassified