2015
DOI: 10.1002/elan.201500329
|View full text |Cite
|
Sign up to set email alerts
|

Square Wave Cathodic Adsorptive Stripping Voltammetric Determination of the Anticancer Drugs Flutamide and Irinotecan in Biological Fluids Using Renewable Pencil Graphite Electrodes

Abstract: 1IntroductionThea ntitumoral activity of flutamide {2-methyl-N-[4-nitro-3-(trifluoro methyl) phenyl] propanamide}( Flu) and irinotecan {7-ethyl-10-[4-(1-piperidino)1-piperidino] carbonyloxy-camptothecin} (Irino)( Scheme 1) against certain types of cancers was previously reported.Flutamide seems to have antiandrogenics pecificity only in androgend ependentg enitalia organs,a nd its therapeuticu se is in prostatic cancer [1][2][3][4].A sf lutamide has as tructure similar to testosterone,i tw orksb ya ttaching it… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(20 citation statements)
references
References 42 publications
0
20
0
Order By: Relevance
“…The LD and limit of quantification (LQ) of dantrolene sodium obtained at PGE (0.052 and 0.158 μ g·mL −1 ) and GCE (0.095 and 0.289 μ g/mL) [ 48 ] indicate a more sensitive determination on PGE. Other proofs of the high sensitivity of the voltammetric determinations using PGE as working electrode are the low LDs and LQs values recorded for flutamide (1.55 · 10 −8 M and 5.16 · 10 −8 M), irinotecan (1.68 · 10 −9 and 5.69 · 10 −9 M) [ 49 ], capsaicin (3.7 · 10 −9 M and 1.2 · 10 −8 M), dihydrocapsaicin (9.1 · 10 −10 M and 3.0 · 10 −9 M) [ 25 ], and paclitaxel (2.46 · 10 −9 M and 8.23 · 10 −9 M) [ 26 ], respectively.…”
Section: Discussionmentioning
confidence: 99%
“…The LD and limit of quantification (LQ) of dantrolene sodium obtained at PGE (0.052 and 0.158 μ g·mL −1 ) and GCE (0.095 and 0.289 μ g/mL) [ 48 ] indicate a more sensitive determination on PGE. Other proofs of the high sensitivity of the voltammetric determinations using PGE as working electrode are the low LDs and LQs values recorded for flutamide (1.55 · 10 −8 M and 5.16 · 10 −8 M), irinotecan (1.68 · 10 −9 and 5.69 · 10 −9 M) [ 49 ], capsaicin (3.7 · 10 −9 M and 1.2 · 10 −8 M), dihydrocapsaicin (9.1 · 10 −10 M and 3.0 · 10 −9 M) [ 25 ], and paclitaxel (2.46 · 10 −9 M and 8.23 · 10 −9 M) [ 26 ], respectively.…”
Section: Discussionmentioning
confidence: 99%
“…In addition to this, a comparison of the proposed sensor with other reported methods (including electrochemical methods) for the detection of utamide has also been carried out, and the results are summarized in Table S1. † [40][41][42][43][44][45] Compared to other electrochemical methods, the proposed method demonstrated higher sensitivity, wide linear response range, lower LOD and very simple electrode fabrication process. Moreover, the proposed sensor was applied in real samples such as in rat brain, kidney and human blood serum samples.…”
Section: Determination Of Utamidementioning
confidence: 99%
“…Other methods were published for determination of Flutamide including electrochemical [ 2 , 9 , 10 ], different spectrophotometric [ 2 , 8 , 11 – 14 ], spectrofluorimetric [ 15 ], and different chromatographic methods [ 2 , 3 , 16 20 ].…”
Section: Introductionmentioning
confidence: 99%