2022
DOI: 10.3390/molecules27165077
|View full text |Cite
|
Sign up to set email alerts
|

Stability, Antioxidant Activity and Intestinal Permeation of Oleuropein Inclusion Complexes with Beta-Cyclodextrin and Hydroxypropyl-Beta-Cyclodextrin

Abstract: Compared to beta-cyclodextrins (beta-CD), hydroxypropyl-beta-cyclodextrins (HP-beta-CD) are a more popular material used to prepare inclusion complexes due to their superior solubility and intestinal absorption. In this study, oleuropein (OL) inclusion complexes with beta-CD (beta-CD:OL) and HP-beta-CD (HP-beta-CD:OL) were prepared and the formation of inclusion complexes was validated by IR, PXRD, and DSC. A phase solubility test showed that the lgK (25 °C) and binding energy of beta-CD:OL and HP-beta-CD:OL w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 45 publications
0
2
0
Order By: Relevance
“…It can be seen from Figure 3 b that MLX had a single sharp melting endothermic peak at about 271 °C, corresponding to the melting temperature of MLX [ 25 ]. Compared to MLX, HP-β-CD ( Figure 3 a) had an endothermic peak of around 75 °C and a complex endothermic peak from 300 to 370 °C, which corresponded with water dissociation from the compound and the melting point and decomposition of HP-β-CD, respectively [ 26 ]. In the physical mixture of MLX and HP-β-CD ( Figure 3 c), there were both endothermic peaks of MLX and HP-β-CD, indicating that there was almost no interaction between the two components.…”
Section: Resultsmentioning
confidence: 99%
“…It can be seen from Figure 3 b that MLX had a single sharp melting endothermic peak at about 271 °C, corresponding to the melting temperature of MLX [ 25 ]. Compared to MLX, HP-β-CD ( Figure 3 a) had an endothermic peak of around 75 °C and a complex endothermic peak from 300 to 370 °C, which corresponded with water dissociation from the compound and the melting point and decomposition of HP-β-CD, respectively [ 26 ]. In the physical mixture of MLX and HP-β-CD ( Figure 3 c), there were both endothermic peaks of MLX and HP-β-CD, indicating that there was almost no interaction between the two components.…”
Section: Resultsmentioning
confidence: 99%
“…At the same time, the characteristic endothermic peak of MA at 159 °C disappears. A small endothermic peak appears at 226 °C, which is the melting temperature of HP-β-CD/MA microcapsules, indicating that MA is successfully embedded in the cavity of HP-β-CD molecules [ 37 ].…”
Section: Resultsmentioning
confidence: 99%