2006
DOI: 10.1002/elan.200603702
|View full text |Cite
|
Sign up to set email alerts
|

Stabilized Lipid Membrane Based Biosensors with Incorporated Enzyme for Repetitive Uses

Abstract: This work reports a technique for the stabilization of lipid membrane based biosensors with incorporated enzyme that retains its activity for repetitive uses. Microporous filters composed of glass fibers were used as supports for the stabilization of these sensors. The lipid film is formed on the filter by polymerization using UV (ultraviolet) radiation prior its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2,2'-azobis-(2-methylpropionitrile) was the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
68
0
10

Year Published

2008
2008
2017
2017

Publication Types

Select...
4
3

Relationship

4
3

Authors

Journals

citations
Cited by 46 publications
(80 citation statements)
references
References 24 publications
2
68
0
10
Order By: Relevance
“…Stabilized lipid films were prepared by polymerization that was previously described in the literature [12,20,21,23,24]. The polymerization took place by using UV irradiation instead of the thermal polymerization; 5 mg of DPPC were mixed with 0.070 mL of methacrylic acid, 0.8 mL of ethylene glycol dimethacrylate, 8 mg of 2,2'-azobis-(2-methylpropionitrile), 1.0 mL of acetonitrile and 0.29 mg of the phosphoryl receptor.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Stabilized lipid films were prepared by polymerization that was previously described in the literature [12,20,21,23,24]. The polymerization took place by using UV irradiation instead of the thermal polymerization; 5 mg of DPPC were mixed with 0.070 mL of methacrylic acid, 0.8 mL of ethylene glycol dimethacrylate, 8 mg of 2,2'-azobis-(2-methylpropionitrile), 1.0 mL of acetonitrile and 0.29 mg of the phosphoryl receptor.…”
Section: Methodsmentioning
confidence: 99%
“…The filter with the mixture was then irradiated using the UV deuterium lamp. Raman spectrometry was used to monitor the kinetics of the process of polymerization [24]. The polymerization was completed within 4 hours.…”
Section: Methodsmentioning
confidence: 99%
“…The formation of stabilized lipid film was previously described [27,30,31]. A complete description of the experimental setup used was described previously in literature [27,30,31].…”
Section: Apparatusmentioning
confidence: 99%
“…A complete description of the experimental setup used was described previously in literature [27,30,31]. One of the Ag/AgCl reference electrodes was immersed in the waste of the carrier electrolyte solution, whereas the other Ag/AgCl reference electrode was placed into the cylindrical cell.…”
Section: Apparatusmentioning
confidence: 99%
“…The construction of the graphene electrode has been described in detail in one of our previous papers [17]; a 0.4 mg/mL homogeneous graphene dispersion had been obtained in N-methyl-pyrrolidone (NMP) after mild sonication (using a Bandelin SONOREX Digital 10P sonicator, Sigma-Aldrich, Taufkirchen Germany) for 180 h and centrifugation at 700 rpm for 2 h. Stabilized lipid films were prepared by polymerization, as previously described in the literature [18,19]. Shortly, 5 mg of DPPC were added to a mixture of 0.070 mL of methylacrylic acid, 0.8 mL of ethylene glycol dimethacrylate, 8 mg of 2,2 -azobis-(2-methylpropionitrile), 1.0 mL of acetonitrile.…”
Section: Fabrication Of the Lipid-based Sensor Electrode With Incorpomentioning
confidence: 99%