Standardization of Eclipta Alba by HPTLC, HPLC and AAS

Abstract: The whole plant of bhringaraj (Eclipta alba) was dried and pulverized. The phytoconstituents of the pulverized plant material were extracted separately with two different solvents namely petroleum ether (hot percolation) and methanol (cold maceration) to carry out a comparative extraction efficiency of the above two solvents. β-sitosterol reported to have antiandrogenic, anticancer, antiinflammatory, antiprostatitic, antitumor, etc. activity, was selected as the active biomarker for quantification of the afore… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…HPTLC method was used to quantify the β-sitosterol reported by Bhattacharjee et al (2017) with minor modifications [23]. The CAMAG HPTLC system consisting of WINCATS software, LINOMAT V automatic sample applicator, an automatic development chamber, scanning densitometer CAMAG scanner 3, and photo documentation apparatus CAMAG reprostar 3 were used.…”
Section: Standardization and Quantification Of β-Sitosterol In Hair G...mentioning
confidence: 99%
See 1 more Smart Citation
“…HPTLC method was used to quantify the β-sitosterol reported by Bhattacharjee et al (2017) with minor modifications [23]. The CAMAG HPTLC system consisting of WINCATS software, LINOMAT V automatic sample applicator, an automatic development chamber, scanning densitometer CAMAG scanner 3, and photo documentation apparatus CAMAG reprostar 3 were used.…”
Section: Standardization and Quantification Of β-Sitosterol In Hair G...mentioning
confidence: 99%
“…HPLC method was performed to quantify the β-sitosterol reported by Bhattacharjee et al (2017) with some modifications [23]. RP-HPLC system (Shimadzu Prominence, Kyoto, Japan) equipped with two Shimadzu LC-20 UFLC reciprocating pumps, a variable Shimadzu SPD-M20A Prominence PDA detector and a rheodyne manual injector with a loop size of 20 μl was used.…”
Section: Standardization and Quantification Of β-Sitosterol In Hair G...mentioning
confidence: 99%
“…12 Standardization of β-sitosterol in E. alba Extracts using HPTLC The approach described by Bhattacharjee et al (2017) has been modified in some respects. 13 CAMAG HPTLC system includes the scanning densitometer, LINOMAT V automated sample applicator, and automatic development chamber, with WINCATS software. The image documentation tools CAMAG Reprostar 3 and CAMAG Scanner 3 were utilized.…”
Section: Qualitative Evaluation Of E Alba Extractsmentioning