2017
DOI: 10.1016/j.dental.2017.01.018
|View full text |Cite
|
Sign up to set email alerts
|

Stereolithography: A new method for processing dental ceramics by additive computer-aided manufacturing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
120
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 175 publications
(123 citation statements)
references
References 24 publications
2
120
1
Order By: Relevance
“…The sample size of each group was ten in the present study; however, Quinn and Quinn recommended a sample size of 30 when Weibull analysis should be conducted . However, several studies have been conducted on fewer than 30 specimens, and Weibull analysis was used . Although a smaller sample size yielded enough data to analyze the Weibull modulus, it is a limitation of the current study.…”
Section: Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…The sample size of each group was ten in the present study; however, Quinn and Quinn recommended a sample size of 30 when Weibull analysis should be conducted . However, several studies have been conducted on fewer than 30 specimens, and Weibull analysis was used . Although a smaller sample size yielded enough data to analyze the Weibull modulus, it is a limitation of the current study.…”
Section: Discussionmentioning
confidence: 88%
“…44 However, several studies have been conducted on fewer than 30 specimens, and Weibull analysis was used. 45,46 Although a smaller sample size yielded enough data to analyze the Weibull modulus, it is a limitation of the current study.…”
Section: Discussionmentioning
confidence: 92%
“…Sintering shrinkage, however, was homogenous for SM specimens in contrast to anisotropic shrinkage for SLA manufactured specimens. The study also demonstrated the feasibility of alumina slurry with large particles and 80% dry matter content for the fabrication of ceramic crown on a maxillary premolar (Figure ).…”
Section: Am Technologies Relevant To the Fabrication Of Dental Ceramicsmentioning
confidence: 90%
“…Marion et al compared the 3 point flexural strengths and Weibull Moduli of SLA manufactured and SM alumina specimens. SLA manufactured specimens with a large particle size and high dry matter content demonstrated similar flexural strengths and Weibull moduli to SM specimens …”
Section: Am Technologies Relevant To the Fabrication Of Dental Ceramicsmentioning
confidence: 99%
See 1 more Smart Citation