2016
DOI: 10.1016/j.engstruct.2016.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Strengthening system using post-tension tendon with an internal anchorage of concrete members

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
3
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 16 publications
(14 reference statements)
1
3
1
Order By: Relevance
“…In this part, the advantage of using HSC clearly appeared. Compared to other studies, the reinforcing level of this study was lower [ 11 , 12 , 14 , 16 , 19 , 20 ]. In particular, Marchão et al [ 16 ] installed lateral reinforcements with 60 mm spacing, and the size of specimens was similar to this study.…”
Section: Resultscontrasting
confidence: 81%
See 2 more Smart Citations
“…In this part, the advantage of using HSC clearly appeared. Compared to other studies, the reinforcing level of this study was lower [ 11 , 12 , 14 , 16 , 19 , 20 ]. In particular, Marchão et al [ 16 ] installed lateral reinforcements with 60 mm spacing, and the size of specimens was similar to this study.…”
Section: Resultscontrasting
confidence: 81%
“…However, SP-N-LT-3 and 4 showed satisfying strain stabilization and exceeding 1.0 Fpk. These results mean that the SP-N-LT-3 and SP-N-LT-4 specimens had the poorest performance, even smaller reinforcing and without spiral reinforcement, comparing other studies [11,12,14,16,19,20,27]. In the same way, the combination of HSC and confinement effect by lateral reinforcement (secondary confining) can be confirmed from the results of Figure 14b.…”
Section: Load-displacement and Reinforcement Strain Resultssupporting
confidence: 77%
See 1 more Smart Citation
“…In the presented paper, simply supported prestressed composite girders with alternating prestressing levels, eccentricity of tendons, and tendon properties are examined. Mimoto et al [15] developed a strengthening system using post-tensioned tendons with internal anchorages in the existing concrete. e internal anchorage hole is made using a special drilling machine, and the system provides joints between the existing and additionally cast concrete parts.…”
Section: Introductionmentioning
confidence: 99%
“…Three main approaches are generally chosen to represent 1D steel members in 3D concrete structures when large-scale structures are considered [10]: the "classical" 1D approach [11], the homogenized 2D approach [12], and the richer "full 3D" approach [13,14].…”
Section: Introductionmentioning
confidence: 99%