Stretchable Capacitive Pressure Sensing Sleeve Deployable onto Catheter Balloons towards Continuous Intra-Abdominal Pressure Monitoring

Abstract: Intra-abdominal pressure (IAP) is closely correlated with intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) diagnoses, indicating the need for continuous monitoring. Early intervention for IAH and ACS has been proven to reduce the rate of morbidity. However, the current IAP monitoring method is a tedious process with a long calibration time for a single time point measurement. Thus, there is the need for an efficient and continuous way of measuring IAP. Herein, a stretchable capacitiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 47 publications
0
10
0
1
Order By: Relevance
“…Despite of the recent development in biodegradable pressure sensors, there are still some issues, such as sensitivity, operating range, and controllability of biodegradability, essentially to be improved for accurate pressure monitoring of various tissues and organs. In other words, regarding there are huge recent demands for healthcare and diagnosis of diseases in early stage through the pressure sensing of diverse tissues and organs, such as intracranial pressure [ 152 , 153 , 154 , 155 , 156 , 157 ], intraocular pressure [ 158 , 159 , 160 , 161 , 162 , 163 ], heartbeat [ 164 , 165 , 166 ], and bladder pressure [ 167 , 168 , 169 , 170 ], we expect that the high-performance biodegradable pressure sensors will be much more important for diverse biomedical applications in the future.…”
Section: Discussionmentioning
confidence: 99%
“…Despite of the recent development in biodegradable pressure sensors, there are still some issues, such as sensitivity, operating range, and controllability of biodegradability, essentially to be improved for accurate pressure monitoring of various tissues and organs. In other words, regarding there are huge recent demands for healthcare and diagnosis of diseases in early stage through the pressure sensing of diverse tissues and organs, such as intracranial pressure [ 152 , 153 , 154 , 155 , 156 , 157 ], intraocular pressure [ 158 , 159 , 160 , 161 , 162 , 163 ], heartbeat [ 164 , 165 , 166 ], and bladder pressure [ 167 , 168 , 169 , 170 ], we expect that the high-performance biodegradable pressure sensors will be much more important for diverse biomedical applications in the future.…”
Section: Discussionmentioning
confidence: 99%
“…However, changes to the volume of the cavity due to body position [ 56 ], muscle composition and contraction [ 57 ], or respiration can substantially change IVP [ 7 ], which limits the accuracy and precision of IVP devices. Kumar et al [ 30 ] reported a stretchable capacitive pressure-sensing sleeve that can detect the pressure change on the Foley tip, which might further improve IVP measurement. Groups from the University of Utah [ 2 , 4 , 45 , 52 ] presented several studies and devices to measure IAP through the transvaginal route.…”
Section: Discussionmentioning
confidence: 99%
“…Diaphragm displacement sensors [ 27 , 30 , 31 ] ( Figure 1 B) have a bendable flat surface (i.e., the diaphragm) and are exposed to the pressure medium on one side. For a pressure sensor, the opposite side is a sealed cavity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…9,10 In addition, another study attached a capacitive sensor on a foley balloon catheter, and the measuring target was intravesical and intraabdominal pressure where the detection range of pressure was under 5 kPa. 11 Both sensors have limitations of a narrow pressure detection range as well as the need for an external power source for operation.…”
Section: Introductionmentioning
confidence: 99%