Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Distinguishing Keratoconus (KC) from other corneal ectatic diseases and thinning disorders is essential for a stage-appropriate and suitable management of each condition. The most relevant corneal pathologies that may imitate the tomographic KC pattern are Pellucid Marginal Degeneration (PMD), Keratoglobus, Posterior Keratoconus and Fuchs Terrien’s Marginal Degeneration (FTMD). In moderate cases of KC, the differentiation is typically possible based on slit-lamp examination and corneal tomography with evaluation of the location of the corneal thinning region. In early cases, however, the differential diagnosis may be more challenging since the cornea may look relatively normal. In severe cases, the extended area of corneal thinning also complicates the differentiation. Biomicroscopic findings cannot always give all the information needed to distinguish KC from related ectatic corneal conditions. Aim of this work is to discuss contemporary techniques and findings to assist physicians in finding the correct diagnosis. Corneal topography has been used in the last decades as the main tool for imaging in ectatic corneal diseases. Moreover, Scheimpflug cameras (corneal tomographers) which analyze both, anterior and posterior corneal surface, curvatures, pachymetry, elevation data, higher order aberrations, Fourier analysis of keratometric data and corneal density became the most promising tools for diagnosis and follow-up of ectatic diseases. A non-invasive air pulse tonometer in conjunction with an ultra-high-speed Scheimpflug camera complements tomographic findings by analysing biomechanical corneal properties. Α confocal microscopy system, which is a novel clinical technique for the study of corneal cellular structure, could contribute effectively towards the same direction. Moreover, anterior segment optical coherence tomography (AS-OCT) creates cross-sections, which can be generated into a three-dimensional structure to produce corneal epithelial thickness (ET) measurements. ET mapping is increasingly recognized as a sensitive tool for the diagnosis of ocular surface disorders. Combining information of all these systems could lead to more effective identification and differential diagnosis of ectatic corneal disorders. Die Unterscheidung zwischen Keratokonus (KK) und anderen ektatischen Hornhauterkrankungen ist für eine angemessene Behandlung der jeweiligen Erkrankung unerlässlich. Die wichtigsten Hornhautpathologien, die bei der Differenzialdiagnose des KK in Betracht gezogen werden müssen, sind die Pelluzide Marginale Degeneration (PMD), der Keratoglobus, der posteriore Keratokonus und die Fuchs-Terrien‘sche Marginale Degeneration (FTMD). In mittelschweren KK-Fällen ist die Differenzierung aufgrund der klassischen Lage der Hornhautverdünnungsregion möglich. In frühen Fällen ist die Differenzialdiagnose jedoch schwierig, da die Hornhaut relativ normal aussehen kann. In fortgeschrittenen Stadien hingegen ist die Differenzierung aufgrund des ausgedehnten Bereichs der Hornhautverdünnung mitunter ebenfalls schwierig. Biomikroskopische Befunde können nicht alle Informationen liefern, die zur Unterscheidung des KK von anderen ektatischen Hornhauterkrankungen erforderlich sind. Daher werden moderne Techniken und Befunde diskutiert, um die richtige Differenzialdiagnose sicher stellen zu können. Hornhauttopographiekarten wurden in den letzten Jahrzehnten als Hauptinstrument für die bildgebende Differenzialdiagnose verwendet. Darüber hinaus wurden Scheimpflug-Kameras (Hornhauttomographen), die sowohl die vordere als auch die hintere Hornhautfläche anhand von Krümmungsdaten, Pachymetrie, Elevationsmessungen, Aberrationen höherer Ordnung, Fourier-Analysen keratometrischer Daten und die Hornhautdichte analysieren, zum wichtigsten Instrument für die Diagnose und Verlaufskontrolle ektatischer Hornhauterkrankungen. Seit neuestem zeichnet ein nicht-invasives Luftstoß-Tonometer in Verbindung mit einer Ultra-Hochgeschwindigkeits-Scheimpflug-Kamera die Reaktion der Hornhaut auf diesen mechanischen Stimulus auf und analysiert so ihre biomechanischen Eigenschaften. Des Weiteren könnte die konfokale Mikroskopie effektiv zur Differentialdiagnose beitragen. Darüber hinaus erzeugt die optische Kohärenztomographie des vorderen Segments (AS-OCT) Querschnitte, die in eine dreidimensionale Struktur umgewandelt werden können, um die Hornhautepitheldicke zu messen. Das Endothel-Mapping wird zunehmend als wirksames Instrument für die Diagnose von Erkrankungen der Augenoberfläche anerkannt. Die Kombination der Informationen all dieser Systeme könnte eine umfassendere Identifizierung und Differenzialdiagnose ektatischer Hornhauterkrankungen ermöglichen.
Distinguishing Keratoconus (KC) from other corneal ectatic diseases and thinning disorders is essential for a stage-appropriate and suitable management of each condition. The most relevant corneal pathologies that may imitate the tomographic KC pattern are Pellucid Marginal Degeneration (PMD), Keratoglobus, Posterior Keratoconus and Fuchs Terrien’s Marginal Degeneration (FTMD). In moderate cases of KC, the differentiation is typically possible based on slit-lamp examination and corneal tomography with evaluation of the location of the corneal thinning region. In early cases, however, the differential diagnosis may be more challenging since the cornea may look relatively normal. In severe cases, the extended area of corneal thinning also complicates the differentiation. Biomicroscopic findings cannot always give all the information needed to distinguish KC from related ectatic corneal conditions. Aim of this work is to discuss contemporary techniques and findings to assist physicians in finding the correct diagnosis. Corneal topography has been used in the last decades as the main tool for imaging in ectatic corneal diseases. Moreover, Scheimpflug cameras (corneal tomographers) which analyze both, anterior and posterior corneal surface, curvatures, pachymetry, elevation data, higher order aberrations, Fourier analysis of keratometric data and corneal density became the most promising tools for diagnosis and follow-up of ectatic diseases. A non-invasive air pulse tonometer in conjunction with an ultra-high-speed Scheimpflug camera complements tomographic findings by analysing biomechanical corneal properties. Α confocal microscopy system, which is a novel clinical technique for the study of corneal cellular structure, could contribute effectively towards the same direction. Moreover, anterior segment optical coherence tomography (AS-OCT) creates cross-sections, which can be generated into a three-dimensional structure to produce corneal epithelial thickness (ET) measurements. ET mapping is increasingly recognized as a sensitive tool for the diagnosis of ocular surface disorders. Combining information of all these systems could lead to more effective identification and differential diagnosis of ectatic corneal disorders. Die Unterscheidung zwischen Keratokonus (KK) und anderen ektatischen Hornhauterkrankungen ist für eine angemessene Behandlung der jeweiligen Erkrankung unerlässlich. Die wichtigsten Hornhautpathologien, die bei der Differenzialdiagnose des KK in Betracht gezogen werden müssen, sind die Pelluzide Marginale Degeneration (PMD), der Keratoglobus, der posteriore Keratokonus und die Fuchs-Terrien‘sche Marginale Degeneration (FTMD). In mittelschweren KK-Fällen ist die Differenzierung aufgrund der klassischen Lage der Hornhautverdünnungsregion möglich. In frühen Fällen ist die Differenzialdiagnose jedoch schwierig, da die Hornhaut relativ normal aussehen kann. In fortgeschrittenen Stadien hingegen ist die Differenzierung aufgrund des ausgedehnten Bereichs der Hornhautverdünnung mitunter ebenfalls schwierig. Biomikroskopische Befunde können nicht alle Informationen liefern, die zur Unterscheidung des KK von anderen ektatischen Hornhauterkrankungen erforderlich sind. Daher werden moderne Techniken und Befunde diskutiert, um die richtige Differenzialdiagnose sicher stellen zu können. Hornhauttopographiekarten wurden in den letzten Jahrzehnten als Hauptinstrument für die bildgebende Differenzialdiagnose verwendet. Darüber hinaus wurden Scheimpflug-Kameras (Hornhauttomographen), die sowohl die vordere als auch die hintere Hornhautfläche anhand von Krümmungsdaten, Pachymetrie, Elevationsmessungen, Aberrationen höherer Ordnung, Fourier-Analysen keratometrischer Daten und die Hornhautdichte analysieren, zum wichtigsten Instrument für die Diagnose und Verlaufskontrolle ektatischer Hornhauterkrankungen. Seit neuestem zeichnet ein nicht-invasives Luftstoß-Tonometer in Verbindung mit einer Ultra-Hochgeschwindigkeits-Scheimpflug-Kamera die Reaktion der Hornhaut auf diesen mechanischen Stimulus auf und analysiert so ihre biomechanischen Eigenschaften. Des Weiteren könnte die konfokale Mikroskopie effektiv zur Differentialdiagnose beitragen. Darüber hinaus erzeugt die optische Kohärenztomographie des vorderen Segments (AS-OCT) Querschnitte, die in eine dreidimensionale Struktur umgewandelt werden können, um die Hornhautepitheldicke zu messen. Das Endothel-Mapping wird zunehmend als wirksames Instrument für die Diagnose von Erkrankungen der Augenoberfläche anerkannt. Die Kombination der Informationen all dieser Systeme könnte eine umfassendere Identifizierung und Differenzialdiagnose ektatischer Hornhauterkrankungen ermöglichen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.