2005
DOI: 10.2116/analsci.21.293
|View full text |Cite
|
Sign up to set email alerts
|

Strontium(II) Sensor Based on a Modified Calix[6]arene in PVC Matrix

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 17 publications
0
11
0
Order By: Relevance
“…The surprisingly high selectivity of the membrane electrode for strontium ions over other cations used most probably arises from the strong tendency of the carrier molecules for strontium ions. Table 3 compares the selectivity coefficients, detection limits, and dynamic linearity range of all Sr 2þ sensors (Shamsipur et al 1999;Jain et al 2004;Gupta, Ludwig, and Agarwal 2005). As is immediately evident, the described sensor is superior to the reported Sr 2þ sensors not only in terms of selectivity but also in terms of detection limit and linearity range.…”
Section: Sr 2+ Electrode Selectivitymentioning
confidence: 82%
See 1 more Smart Citation
“…The surprisingly high selectivity of the membrane electrode for strontium ions over other cations used most probably arises from the strong tendency of the carrier molecules for strontium ions. Table 3 compares the selectivity coefficients, detection limits, and dynamic linearity range of all Sr 2þ sensors (Shamsipur et al 1999;Jain et al 2004;Gupta, Ludwig, and Agarwal 2005). As is immediately evident, the described sensor is superior to the reported Sr 2þ sensors not only in terms of selectivity but also in terms of detection limit and linearity range.…”
Section: Sr 2+ Electrode Selectivitymentioning
confidence: 82%
“…In spite of providing an accurate determination, these methods are not appropriate because they demand high cost and sample pretreatment. There have been some reports of ion-selective strontium electrodes in the literature (Shamsipur et al 1999;Jain et al 2004;Gupta, Ludwig, and Agarwal 2005;Zamani et al 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Zhang and coworkers came up with the new methodology for the partitioning of Sr 2+ from nuclear waste using two macroporous silica‐based polymeric composites. Calixarenes are also widely tested by many researchers as a possible extractant for Sr 2+ .…”
Section: Introductionmentioning
confidence: 99%
“…A survey on the literature proves that there exist only a limited number of reports on selective determination of Sm 3+ ions in the presence of other rare earth elements by electrochemical method [3][4][5][6][7]. Numerous reports on the selective and sensitive PVC-membrane ISEs have recently been published [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26] which made us believe another ion selective sensor could be introduced for the potentiometric determination of Sm 3+ ion based on N,N′,N″-tris(4-pyridyl)trimesic amide (TPTA) (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%