2017
DOI: 10.3390/s17051155
|View full text |Cite
|
Sign up to set email alerts
|

Structural Analysis of Polymer Composites Using Spectral Domain Optical Coherence Tomography

Abstract: The structural analysis of nylon/graphene oxide (NY/GO) and polyetherblockamide/ trisilinolphenyl-polyhederal oligomeric silsesquioxane (PEBA/t-POSS) composites were performed using high-resolution spectral domain optical coherence tomography (SD-OCT). This optical technology revealed both cross-sectional, as well as sub-layer depth information of sample. The non-destructive real-time imaging demonstrated the nature of defects in the composites. The thickness and location of each defect point in the composites… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 46 publications
0
9
0
Order By: Relevance
“…Although related assessments were not descriptively studied, vision inspection based quantifications of previously reported defect inspection studies were well considered for baseline comparisons [36,37]. In previous studies [21,35,[38][39][40][41], non-destructive identification of industrial materials has been achieved for diverse industrial materials. However, to date, a VLSC-synchronized with dual SD-OCT multimodal image inspection system for examining OTF sample defects in real time has not been studied in detail.…”
Section: Discussionmentioning
confidence: 99%
“…Although related assessments were not descriptively studied, vision inspection based quantifications of previously reported defect inspection studies were well considered for baseline comparisons [36,37]. In previous studies [21,35,[38][39][40][41], non-destructive identification of industrial materials has been achieved for diverse industrial materials. However, to date, a VLSC-synchronized with dual SD-OCT multimodal image inspection system for examining OTF sample defects in real time has not been studied in detail.…”
Section: Discussionmentioning
confidence: 99%
“…OCT is widely used for both structural and functional imaging applications for disease diagnosis such as that of the eye [3], [4], heart and blood vessels [5], [6], [7], [8] , tumours [9], [10], visualization of dental structure [11], [12], [13], diagnosis and treatment of skin disorders [14], [15], [16]. OCT is used for imaging in material science [17], structural analysis of polymer composites [18], [19], sensor technology [20], [21], among many other applications. Spectral-domain OCT (SD-OCT) is a widely used modality due to its high sensitivity and fast imaging speed [22], [23], [24], [25], [26].…”
Section: Introductionmentioning
confidence: 99%
“…Periodic alternation of refractive index in these materials allows them to reflect the light, observable in the visible region . So far, several fabrication methods have been developed to fabricate responsive one-, two-, and three-dimensional PCs; for example, stimuli-responsive PCs have received much interest in the last few decades for their possible applications in optical sensors. , Hydrogels with integrated photonic band gap structures have been optimized to undergo reversible changes in their physical dimensions in response to external stimuli such as glucose, pH, ionic strength, temperature, humidity, solvent composition, and biomolecule binding. The photonic band gaps of these sensors are sensitive to such a volumetric change, which is converted into readable optical information.…”
Section: Introductionmentioning
confidence: 99%