2015
DOI: 10.1016/j.porgcoat.2015.08.011
|View full text |Cite
|
Sign up to set email alerts
|

Structural and anticorrosion performance characterization of phosphosilicate sol–gel coatings prepared from 3-(trimethoxysilyl) propyl methacrylate and bis[2-(methacryloyloxy)ethyl] phosphate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 23 publications
0
1
0
Order By: Relevance
“…Sol-gel coatings prepared from condensation and polymerization of TEOS and MAPTS, TEOS and MTES, TMOS and MAPTS, or TMOS and MTES mixtures in three molar ratios were also reported by Criado et al [79,80]. For carbon steel, hybrid sol-gel coatings prepared from 3-(trimethoxysilyl) propyl methacrylate and bis [2-(methacryloyloxy) ethyl] phosphate via the sol-gel process [81] were applied. Generally, the recent publications, from 2013 to 2015 are following a tendency found previously [58], where the majority of the reported papers on this substrates use TEOS; GPTMS, MAPTS, and MTES.…”
Section: Corrosion Protective Sol-gel Coatings In Steel Substratesmentioning
confidence: 94%
“…Sol-gel coatings prepared from condensation and polymerization of TEOS and MAPTS, TEOS and MTES, TMOS and MAPTS, or TMOS and MTES mixtures in three molar ratios were also reported by Criado et al [79,80]. For carbon steel, hybrid sol-gel coatings prepared from 3-(trimethoxysilyl) propyl methacrylate and bis [2-(methacryloyloxy) ethyl] phosphate via the sol-gel process [81] were applied. Generally, the recent publications, from 2013 to 2015 are following a tendency found previously [58], where the majority of the reported papers on this substrates use TEOS; GPTMS, MAPTS, and MTES.…”
Section: Corrosion Protective Sol-gel Coatings In Steel Substratesmentioning
confidence: 94%
“…Coated panels were vertically introduced in the setup into a three-electrode system described elsewhere [42][43][44]. A circular area of 7.55 cm 2 was exposed to a 3 wt% NaCl aqueous solution at 30 • C. The 3 wt% solution was chosen as it has a high corrosion rate on iron and can be easily compared to the literature [5,45,46].…”
Section: Open Circuit Potentialmentioning
confidence: 99%
“…AC impedance measurements were performed using a potentiostat Solartron SI 1287 and a Solartron 1255B (Massy, France) frequency response analyzer and ZPlot 2.80 (Scribner Associates Inc., Southern Pines, NC, USA) software was used to run the tests and to collect the experimental data. The impedance data were fitted with different equivalent circuits using with the simulation ZView 2.80 (Scribner Associates Inc., Southern Pines, NC, USA) equivalent circuit software [42][43][44]. The measurements were carried out over periods ranging from 1 h of exposure to 3 weeks.…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%