2019
DOI: 10.1016/j.ijleo.2019.03.118
|View full text |Cite
|
Sign up to set email alerts
|

Structural and optical properties of chitosan–poly(amidoamine) dendrimer composite thin film for potential sensing Pb2+ using an optical spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 43 publications
0
11
0
Order By: Relevance
“…As powerful analytical tools that have enjoyed widespread attention over the past two decades, SPR sensors have been developed in several configurations to detect several analytes. These sensors serve in different fields such as medical diagnostics [318][319][320][321][322], food quality [323,324], environmental protection [325][326][327][328][329][330][331] and others. SPR, a refractive index-based detection technique has emerged as a promising sensing platform for sensitive detection of NTs, especially DA due to its substantial advantages.…”
Section: Surface Plasmon Resonance Spectroscopymentioning
confidence: 99%
“…As powerful analytical tools that have enjoyed widespread attention over the past two decades, SPR sensors have been developed in several configurations to detect several analytes. These sensors serve in different fields such as medical diagnostics [318][319][320][321][322], food quality [323,324], environmental protection [325][326][327][328][329][330][331] and others. SPR, a refractive index-based detection technique has emerged as a promising sensing platform for sensitive detection of NTs, especially DA due to its substantial advantages.…”
Section: Surface Plasmon Resonance Spectroscopymentioning
confidence: 99%
“…An optical-based sensing method based on surface plasmon resonance (SPR) was designed to identify the potential of the Cs/Fe 2 O 3 thin film to detect Hg 2+ . Figure 1 shows the schematic diagram of the SPR instrument setup [58][59][60][61]. The SPR experiment was carried out by inserting Hg 2+ solutions with different concentration varied from 0.01 to 0.5 ppm.…”
Section: Instrumentalmentioning
confidence: 99%
“…Surface plasmon resonance (SPR) sensing. SPR measurements were conducted based on Kretschmann configuration [65][66][67][68] by evaporating Au/DSU/NH 2 rGO-PAMAM/IgM sensor film onto the prism surface. The prism was placed on an optical stage driven by a stepper motor with a resolution of 0.001° (Newport MM 3000) to let the incident light from laser beam (632.8 nm, 5 mW) pass through the prism and hits a gold layer to generate the surface plasmon waves at the interface.…”
mentioning
confidence: 99%