2013
DOI: 10.1016/j.conbuildmat.2013.05.017
|View full text |Cite
|
Sign up to set email alerts
|

Structural reliability of bonding between steel rebars and recycled aggregate concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 61 publications
(15 citation statements)
references
References 9 publications
1
14
0
Order By: Relevance
“…The results obtained by Breccolotti and Materazzi, Kim and Yun and Guerra et al are consistent with the above results where no significant effect of recycled aggregates on the bond characteristics of concrete is found. It should be noticed that all these studies were conducted by replacing one type of aggregates which is mainly the coarse aggregates.…”
Section: Introductionsupporting
confidence: 88%
See 1 more Smart Citation
“…The results obtained by Breccolotti and Materazzi, Kim and Yun and Guerra et al are consistent with the above results where no significant effect of recycled aggregates on the bond characteristics of concrete is found. It should be noticed that all these studies were conducted by replacing one type of aggregates which is mainly the coarse aggregates.…”
Section: Introductionsupporting
confidence: 88%
“…To ensure that the rebar was in a straight vertical position, a specific molding table was designed (Figure ). The specimen's geometry has been preceded by a feasibility study based on a bibliographical study …”
Section: Experimental Programmentioning
confidence: 99%
“…Corinaldesi and Moriconi [14], Kim et al [19], Ajdukiewicz and Kliszczewicz [20], Breccolotti and Materazzi [30], Prince and Singh [31,32] have used pullout test method for investigation bond between reinforcement and concrete. The recycled coarse aggregate used by them were used without any treatment such acid, mechanical, thermal, etc., However the aggregates were soaked in water for a period of 24 h and used at saturated surface dry condition.…”
Section: Compressive Strength the Compressive Strength Results Presementioning
confidence: 99%
“…This way, the employment of pull out test should be considerate in order to improve more information about the reinforced concrete behavior [4] and, in addition can be used for provide forecast on compressive strength of concrete.…”
Section: Introductionmentioning
confidence: 99%
“…However, only in the 70 decade, the studies on RR-C bond characteristics were oriented aiming the obtainment of relations between the mechanical properties of the concrete and the cement. Now, the bond RR-C has been performed in terms of numerical modeling and the zone characteristics implemented aiming a most real model about the behavior of rebar-concrete surrounding zone [4][5][6].…”
Section: Introductionmentioning
confidence: 99%