1998
DOI: 10.1016/s0378-4347(97)00547-1
|View full text |Cite
|
Sign up to set email alerts
|

Study of factors affecting the determination of total plasma 7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate (SBD)–thiol derivatives by liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
21
0
1

Year Published

2001
2001
2012
2012

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(24 citation statements)
references
References 25 publications
2
21
0
1
Order By: Relevance
“…A broad range of SBD-F concentration used for the derivatization can be found from the literature. Some were comparable to the one utilized in this study (Rizzo et al 1998;Frick et al 2003;Nolin et al 2007), while others were much higher. For example, 0.6% was used by Yoshida (Yoshida et al 2003), 0.3% used by Oe (Oe et al 1998) and 0.6 mg/ml by Dashalakis (Daskalakis et al 1996).…”
Section: ; Al-farawati and Van Den Berg 2001) For Quantitative Asupporting
confidence: 71%
See 2 more Smart Citations
“…A broad range of SBD-F concentration used for the derivatization can be found from the literature. Some were comparable to the one utilized in this study (Rizzo et al 1998;Frick et al 2003;Nolin et al 2007), while others were much higher. For example, 0.6% was used by Yoshida (Yoshida et al 2003), 0.3% used by Oe (Oe et al 1998) and 0.6 mg/ml by Dashalakis (Daskalakis et al 1996).…”
Section: ; Al-farawati and Van Den Berg 2001) For Quantitative Asupporting
confidence: 71%
“…The reagents themselves are not fluorescent. Therefore, the interferences from the excess reagent can be avoided (Imai et al 1994;Daskalakis et al 1996;Oe et al 1998;Rizzo et al 1998;Pfeiffer et al 1999;Uchiyama et al 2001;Abukhalaf et al 2002;Yoshida et al 2003).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The SBD-F method has been used to determine low-molecular weight thiols, such as cysteine, homocysteine and glutathione, in plasma (Araki and Sako, 1987;Rizzo et al, 1998;Oe et al, 1998) and high-molecular weight metallothioneins (Miyairi et al, 1998).…”
Section: )mentioning
confidence: 99%
“…The modifications introduced to this procedure account mainly for the non-proteinic matrix analyzed in our study, as well as the smaller volumes used to economize the use of reagents. In addition, recent improvements reported in the literature (Rizzo et al, 1998;Oe et al, 1998;Miyairi et al, 1998) were taken into account as further explained below. This test applies to the determination of reduced and oxidized thiols in water samples by HPLC with fluorescence detection.…”
Section: Fluorimetric Assay Of Thiols With Sbd-fmentioning
confidence: 99%