Study of the temperature dependence of the sensitivity of a television camera based on a silicon array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
0
0
2

Year Published

2017
2017
2019
2019

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
0
0
2
Order By: Relevance
“…In winter, the temperature lowers down to -50°С and lower. Such temperature conditions exert a negative effect on hardware components of electronic devices causing, at least, distortion of the results obtained [2] and reduction of their operational life. In electronic devices, specific physical processes occur under low temperature conditions, such as mechanical damages due to either reduction in thermal strength of assembly components or deformation caused by the difference in thermal expansion coefficients of assembly components made of different materials.…”
Section: Fig 1 Schematic Of X-ray Flat Panel Detectormentioning
confidence: 99%
“…In winter, the temperature lowers down to -50°С and lower. Such temperature conditions exert a negative effect on hardware components of electronic devices causing, at least, distortion of the results obtained [2] and reduction of their operational life. In electronic devices, specific physical processes occur under low temperature conditions, such as mechanical damages due to either reduction in thermal strength of assembly components or deformation caused by the difference in thermal expansion coefficients of assembly components made of different materials.…”
Section: Fig 1 Schematic Of X-ray Flat Panel Detectormentioning
confidence: 99%
“…Анализ и сравнение полученных сведений и результатов для камеры на ПЗС-матрице [6] показы-вают, что температурные зависимости чувствительности кремниевых матриц не имеют принципиальных отличий и в целом подобны аналогичным зависимостям фотодиодов [10][11][12]. Но на характер температур-ной зависимости чувствительности телекамер оказывают влияние не сами технологии изготовления мат-ричных фотоприемных устройств (ПЗС или КМОП), а особенности состава и концентрации примесей кремниевых чувствительных элементов матриц.…”
Section: заключениеunclassified
“…Результаты ранее выполненных исследований температурной зависимости чувствительности циф-ровой камеры на основе ПЗС-матрицы [6] показали, что в красном и ближнем инфракрасном участках спектра температурный коэффициент изменения чувствительности составляет 0,5-1,0 %/К.…”
Section: Introductionunclassified