2014
DOI: 10.3151/jact.12.413
|View full text |Cite
|
Sign up to set email alerts
|

Study on Load-Slip Characteristic Curves of Perfobond Shear Connectors in Hybrid Structures

Abstract: Load-slip characteristic of shear connectors is the basis of connectors' stiffness inputting in finite element analysis and load transfer study of shear connector groups. Based on three series and 24 groups large-scale experiments of perfobond strip shear connectors (PBL) and depended on the cutting-edge measurement techniques of distributed optical fiber sensors, mechanic characteristics and important influence factors were analyzed thoroughly, corresponding formula for ultimate bearing capacity of PBL connec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
22
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(24 citation statements)
references
References 9 publications
2
22
0
Order By: Relevance
“…For groups R-b1r1d0 and RF-b1r1d0, with a 20 mm diameter steel rebar at the 21 mm diameter hole and almost no concrete dowel surrounding the rebar, the transverse rebar was also sheared off directly at the plate/concrete interfaces. For groups R-b0r1d1, R-b1r1d1, RF-b0r1d1, and RF-b1r1d1, with a 20 mm diameter rebar inside concrete dowel passing through the 60 mm diameter hole, the transverse rebar presented a tension/ shear failure mode, similar to PBL embedded in conventional concrete that were previously observed and reported by Wang et al [6], Su et al [8] and He et al [22]. Fig.…”
Section: Failure Modessupporting
confidence: 73%
See 3 more Smart Citations
“…For groups R-b1r1d0 and RF-b1r1d0, with a 20 mm diameter steel rebar at the 21 mm diameter hole and almost no concrete dowel surrounding the rebar, the transverse rebar was also sheared off directly at the plate/concrete interfaces. For groups R-b0r1d1, R-b1r1d1, RF-b0r1d1, and RF-b1r1d1, with a 20 mm diameter rebar inside concrete dowel passing through the 60 mm diameter hole, the transverse rebar presented a tension/ shear failure mode, similar to PBL embedded in conventional concrete that were previously observed and reported by Wang et al [6], Su et al [8] and He et al [22]. Fig.…”
Section: Failure Modessupporting
confidence: 73%
“…Meanwhile, PBLs in hybrid girders have much stronger interfacial restraints and the interfacial bond at the contact surface between perforated plate and concrete is more significant as compared with those in the superimposed beams [6]. As sufficient quantity of PBLs are used to transfer the major shear forces between steel components and concrete in hybrid girders, the effect of local concrete at the end of the perforated plate is small and can be negligible [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In China, Zhang, Z. H. [6], Wang, W. A. [7], He, S. H. [8] et al studied a large number of model tests and finite element studies on PBL shear connectors.…”
Section: Introductionmentioning
confidence: 99%