2019
DOI: 10.1016/j.jsb.2019.03.007
|View full text |Cite
|
Sign up to set email alerts
|

Sub-3 Å apoferritin structure determined with full range of phase shifts using a single position of volta phase plate

Abstract: Volta Phase Plate (VPP) has become an invaluable tool for cryo-EM structural determination of small protein complexes by increasing image contrast. Currently, the standard protocol of VPP usage periodically changes the VPP position to a fresh spot during data collection. Such a protocol was to target the phase shifts to a relatively narrow range (around 90°) based on the observations of increased phase shifts and image blur associated with more images taken with a single VPP position. Here, we report a 2.87 Å … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
23
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(26 citation statements)
references
References 26 publications
3
23
0
Order By: Relevance
“…2) is negative, both halves of the split data are affected, and so the correlation coefficient between halves is positive even if the resulting reconstruction has a negative correlation with the truth. If the coma causes very strong modulation in the FSC (11), then it is easy to recognize the correct resolution limit corresponding to the first zero of the Bessel function J 0 (Eq. 1, 2).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…2) is negative, both halves of the split data are affected, and so the correlation coefficient between halves is positive even if the resulting reconstruction has a negative correlation with the truth. If the coma causes very strong modulation in the FSC (11), then it is easy to recognize the correct resolution limit corresponding to the first zero of the Bessel function J 0 (Eq. 1, 2).…”
Section: Resultsmentioning
confidence: 99%
“…The problem generated by the presence of large coma was analyzed in a recent publication (11) which described the refinement of EMPIAR 10263, dataset III, with coma refinement performed by Relion 3.0 (13) and JSPR (11, 22), with results presented in Fig. 6B in (11). We reprocessed this dataset and obtained a much tighter clustering of coma values, similar to the clustering observed for our datasets.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Interestingly, most of the reconstructions resolved at a resolution of 2 Å or better correspond to apoferritin from various organisms ( Fig 1D, Fig 1E, Table S1), as a result of its high symmetry and intrinsic stability. Indeed, apoferritin is now commonly used as a standard sample to assess microscope performance and implement developments in cryo-EM [5], [9], [10], [11].…”
Section: Textmentioning
confidence: 99%