2020
DOI: 10.1109/tthz.2020.2984459
|View full text |Cite
|
Sign up to set email alerts
|

Sub-Terahertz High-Sensitivity High-Resolution Molecular Spectroscopy With a Gyrotron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(8 citation statements)
references
References 46 publications
0
8
0
Order By: Relevance
“…The radioacoustic spectrometer 45–48 was used for recording the R(0) and R(1) line profiles in the pressure range from several dozen of mTorr up to several torr at room temperature (the cell temperature was stabilized by using the active thermostat within ∼0.5 K). These recordings contained 201 or 151 frequency points, but due to the high stability of temperature and pressure in the short 10 cm gas cell (which is much simpler to implement than in the 2 m video cell), multiple recordings were performed with averaging of the recorded spectra.…”
Section: Experimental Techniques and Data Processingmentioning
confidence: 99%
“…The radioacoustic spectrometer 45–48 was used for recording the R(0) and R(1) line profiles in the pressure range from several dozen of mTorr up to several torr at room temperature (the cell temperature was stabilized by using the active thermostat within ∼0.5 K). These recordings contained 201 or 151 frequency points, but due to the high stability of temperature and pressure in the short 10 cm gas cell (which is much simpler to implement than in the 2 m video cell), multiple recordings were performed with averaging of the recorded spectra.…”
Section: Experimental Techniques and Data Processingmentioning
confidence: 99%
“…Recently, the phase-lock loop stabilized gyrotron was used in experiments for recording characteristic lines in pure gases and gas mixtures by the methods of RAD spectroscopy [33], [34].…”
Section: Development Of Thz-band Gyrotronsmentioning
confidence: 99%
“…IAP has achieved significant progress in the development of mode conversion methods [46]. Quasi-optical mode converters transformers are capable of converting such complex modes as ТЕ 25,10 , ТЕ 28,12 , and ТЕ 34,19 to Gaussian beams (eigenmodes of mirror waveguides) with an efficiency of 95-97% ( Fig. 7), while ensuring that the structures formed in the waveguide cross sections are optimal for this or that assembly unit, e.g., for the output window of the gyrotron [47].…”
Section: Electrodynamics Of Multimode Systemsmentioning
confidence: 99%
“…A spectrometer with radioacoustic detection of absorption (RAD) [33][34][35][36] was used for line profile studies in the pressure range 0.1-2 Torr (Fig. 1B).…”
Section: B Radioacoustic Detection Spectrometermentioning
confidence: 99%