2012
DOI: 10.1016/j.fertnstert.2012.07.1128
|View full text |Cite
|
Sign up to set email alerts
|

Successful delivery derived from vitrified-warmed spermatozoa from a patient with nonobstructive azoospermia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
48
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 37 publications
(48 citation statements)
references
References 16 publications
0
48
0
Order By: Relevance
“…The sperm ultra‐rapid cryopreservation was performed using Cryotop as previously described (Endo et al ., ,b). Briefly, a droplet of 0.5 μl freezing medium was placed on the polypropylene strip of a Cryotop (Kitazato, Tokyo, Japan) at room temperature.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sperm ultra‐rapid cryopreservation was performed using Cryotop as previously described (Endo et al ., ,b). Briefly, a droplet of 0.5 μl freezing medium was placed on the polypropylene strip of a Cryotop (Kitazato, Tokyo, Japan) at room temperature.…”
Section: Methodsmentioning
confidence: 99%
“…Until recently, Endo et al . (, ,b) reported that a small number of human spermatozoa can be successful vitrified using Cryotop. This indicated that Cryotop may be also a suitable carrier to cryopreserve human spermatozoa.…”
Section: Introductionmentioning
confidence: 99%
“…Such changes in culture conditions have been shown to be involved in the lipid peroxidation of cell membranes, nuclear DNA fragmentation, and delay of embryo development [5][6][7][8]. Several groups have reported the cryopreservation of a small number of sperm using devices for embryo vitrification [9,10] by embedding them into an alginate gel [11] and by injecting them into an empty zona pellucida (ZP) [12][13][14]. Sperm injection into an empty ZP is preferable to other methods because of low reproducibility in the vitrification device and reduced survival in the alginate gel.…”
Section: Introductionmentioning
confidence: 99%
“…This device is suitable to handle small cells and has become popular in assisted reproductive clinics. In addition, it was recently successful for sperm cryopreservation by the CryoTop (9). Although the CryoTop is superior for cryopreservation of few spermatozoa, the spermatozoa were loaded into a small freezing drop on the top of the sheet by a manipulator in air.…”
Section: Discussionmentioning
confidence: 99%
“…Some investigators have reported that spermatozoa have been cryopreserved in a very small drop on a tip of CryoLoop or CryoTop. These devices had been developed to freeze embryos (7)(8)(9). However, it is difficult to find all spermatozoa immediately after thawing using these methods because the spermatozoa are very small compared with embryos.…”
mentioning
confidence: 99%