2018
DOI: 10.1002/dta.2481
|View full text |Cite
|
Sign up to set email alerts
|

Suitability evaluation of new endogenous biomarkers for the identification of nitrite‐based urine adulteration in mass spectrometry methods

Abstract: Urine adulteration to circumvent positive drug testing is a fundamental challenge for toxicological laboratories all over the world. Untargeted mass spectrometry (MS) methods used in metabolomics had previously revealed uric acid (UA), histidine, methylhistidine, and their oxidation products, for example 5-hydroxyisourate (HIU) as potential biomarkers for urine adulteration using potassium nitrite (KNO ). These markers should be further evaluated for their reliability, stability, and routine applicability. Inf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
25
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 12 publications
(25 citation statements)
references
References 35 publications
0
25
0
Order By: Relevance
“…Another example is an acute paracetamol poisoning. 12 Steuer et al [13][14][15][16] described interesting metabolomic strategies for detection of sample manipulations using liquid chromatography-high resolution mass spectrometry (LC-HRMS). 4 Pitfalls concerning TDM in dried blood spots (DBS) are reviewed by Antunes et al 5 with special focus on influence of the hematocrit on the plasma concentrations.…”
Section: Samplingmentioning
confidence: 99%
“…Another example is an acute paracetamol poisoning. 12 Steuer et al [13][14][15][16] described interesting metabolomic strategies for detection of sample manipulations using liquid chromatography-high resolution mass spectrometry (LC-HRMS). 4 Pitfalls concerning TDM in dried blood spots (DBS) are reviewed by Antunes et al 5 with special focus on influence of the hematocrit on the plasma concentrations.…”
Section: Samplingmentioning
confidence: 99%
“…Experiments on KNO 2 were described elsewhere. 13 ROC curves, potential cut-offs, sensitivity and specificity were calculated using both MetaboAnalyst 4.0 using the method closest to left corner combining best specificity and best sensitivity 22 and GraphPad Prism 7.0 (GraphPad Software, La Jolla, CA, USA). 13 ROC curves, potential cut-offs, sensitivity and specificity were calculated using both MetaboAnalyst 4.0 using the method closest to left corner combining best specificity and best sensitivity 22 and GraphPad Prism 7.0 (GraphPad Software, La Jolla, CA, USA).…”
Section: Data Analysis For Concentration and Ph Influence And Biomamentioning
confidence: 99%
“…4,9,10 With recent intentions in several US states to ban artificial urine products, chemical adulteration attempts might become of higher interest. 13 To unambiguously identify urine adulteration attempts, a suitable biomarker needs to comprise the ability to reliably differentiate a However, for a broad applicability of these markers, more data are needed considering the large variety of different chemical adulterants. Kluge et al recently evaluated the potential of co-measurement of selected endogenous compounds in an untargeted screening approach for identification of artificial urine products.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations