2005
DOI: 10.1002/jssc.200500005
|View full text |Cite
|
Sign up to set email alerts
|

Supercritical fluid chromatography tandem‐column method development in pharmaceutical sciences for a mixture of four stereoisomers

Abstract: A tandem-column method using Chiralpak AD-H and Chiralcel OD-H columns was achieved for baseline separation of a mixture of chiral pharmaceutical compounds (i.e., four stereoisomers) via supercritical fluid chromatography (SFC) with a mobile phase consisting of 90% liquid carbon dioxide and 10% ethanol:isopropanol (50:50 v/v). On the contrary, this mixture (mixture A) could not be baseline separated by SFC conditions explored with individual Chiralpak AD-H and Chiralcel OD-H columns. The effects of various mob… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0
1

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(21 citation statements)
references
References 29 publications
0
20
0
1
Order By: Relevance
“…[36], the use of coupled columns in SFC analysis was demonstrated to separate four stereoisomers in a mixture (names not specified). Two columns were used, i. e., Chiralcel OD and Chiralpak AD.…”
Section: Separations On Polysaccharide-based Cspmentioning
confidence: 99%
See 1 more Smart Citation
“…[36], the use of coupled columns in SFC analysis was demonstrated to separate four stereoisomers in a mixture (names not specified). Two columns were used, i. e., Chiralcel OD and Chiralpak AD.…”
Section: Separations On Polysaccharide-based Cspmentioning
confidence: 99%
“…Besides the development of the analytical separation of the mixture of four stereoisomers [36] (see Section 2.1.2), the preparative separation of 1 mg mixture was briefly demonstrated, and could be completed within 24 min. Other analysis conditions were a flow rate of 55 mL/min at 408C and 120 bar.…”
Section: Chiral Separations Using Preparative Sfcmentioning
confidence: 99%
“…First, a wider range of CSPs will be tested, but derivatization of targeted molecule and column coupling can also be envisaged. Recently the SFC coupling of two different chiral columns in series has been reported for the resolution of the four stereoisomers of pharmaceutical compounds containing two chiral centers [168,169].…”
Section: The Domination Of the Polysaccharide Chiral Stationary Phasesmentioning
confidence: 99%
“…The recent developments in analytical supercritical fluid chromatography (SFC)-MS as a promising and robust approach for small molecule analysis or purification may provide solutions for some of these issues [32][33][34][35]. Still, further improvements are needed, especially for the analysis of enantiomeric purity and molecular identity.…”
Section: Open-access Analysismentioning