2012
DOI: 10.3390/molecules17032628
|View full text |Cite
|
Sign up to set email alerts
|

Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

Abstract: Abstract:Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
3

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 34 publications
0
7
0
3
Order By: Relevance
“…Pada saat ini, kemajuan metodologi untuk menganalisis komunitas mikroba dari berbagai jenis sampel telah memungkinkan kita untuk mengetahui secara lebih detail komposisi dan fungsi komunitas mikroba tersebut. Namun, pengembangan dan penerapan metode yang lebih handal untuk memperoleh pemahaman secara komprehensif tentang struktur komunitas mikrobia masih merupakan tantangan [4].…”
Section: Pendahuluanunclassified
“…Pada saat ini, kemajuan metodologi untuk menganalisis komunitas mikroba dari berbagai jenis sampel telah memungkinkan kita untuk mengetahui secara lebih detail komposisi dan fungsi komunitas mikroba tersebut. Namun, pengembangan dan penerapan metode yang lebih handal untuk memperoleh pemahaman secara komprehensif tentang struktur komunitas mikrobia masih merupakan tantangan [4].…”
Section: Pendahuluanunclassified
“…The analysis was performed at 35 ± 1 ∘ C with a chromatographic run time of 50 min. The autosampler temperature was set at 4.0 ± 1 ∘ C and the sample injection volume was 10 L [13].…”
Section: Ultra Performance Liquid Chromatography Analysismentioning
confidence: 99%
“…They discovered that SFE, with a solid-phase cartridge trap, proved to be a more rapid and effective method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. The method could significantly reduce the complexity in the procedure and time required for sample preparation [13].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations