2016
DOI: 10.1080/00405000.2016.1171028
|View full text |Cite
|
Sign up to set email alerts
|

Superhydrophobic and ultraviolet protective nylon fabrics by modified nano silica coating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(21 citation statements)
references
References 26 publications
1
20
0
Order By: Relevance
“…UV‐DRS spectra of uncoated (line A), neat extract (curve B) and extract containing AuNPs coated cotton (curve C) are presented in Figure . Both the coated and uncoated cotton fabrics were studied for UV penetration efficiency by calculating the ultraviolet protection factor value (UPF) and observed over the wavelength ranging from 280 to 400 nm . The calculated UPF value of AuNPs coated cotton fabric was found to be 16, which is categorized as good protection efficiency according to the standard.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…UV‐DRS spectra of uncoated (line A), neat extract (curve B) and extract containing AuNPs coated cotton (curve C) are presented in Figure . Both the coated and uncoated cotton fabrics were studied for UV penetration efficiency by calculating the ultraviolet protection factor value (UPF) and observed over the wavelength ranging from 280 to 400 nm . The calculated UPF value of AuNPs coated cotton fabric was found to be 16, which is categorized as good protection efficiency according to the standard.…”
Section: Resultsmentioning
confidence: 99%
“…Both the coated and uncoated cotton fabrics were studied for UV penetration efficiency by calculating the ultraviolet protection factor value (UPF) and observed over the wavelength ranging from 280 to 400 nm. [67,68] The calculated UPF value of AuNPs F I G U R E 6 HR-TEM with SAED images of AuNPs obtained from 0.001 M (A and B), 0.01 M (C and D) of chloroauric acid coated cotton fabric was found to be 16, which is categorized as good protection efficiency according to the standard. The computed UPF values are 3.96 and 8.94 for uncoated-and extract-coated cotton, respectively.…”
Section: Uv-drs Spectral Analysismentioning
confidence: 99%
“…As a result of that, the fabric samples imparted excellent UV protection with +50 UPF and superhydrophobic properties. The fabric samples had still excellent UV protection and hydrophobic properties after 10 washing cycles [35].…”
Section: Water or Oil Repellency Finish (Hydrophobic Effect)mentioning
confidence: 98%
“…Teli and Annaldewar [35] studied the water repellency and UV-protection properties of cotton fabric dip coated with silica nanoparticles prepared by sol-gel process and subsequently impregnated with zinc nitrate hexahydrate in hexamine and then hydrophobically modified with ethanolic sodium stearate solution. As a result of that, the fabric samples imparted excellent UV protection with +50 UPF and superhydrophobic properties.…”
Section: Water or Oil Repellency Finish (Hydrophobic Effect)mentioning
confidence: 99%
“…Some types of sol-gel systems also have bacteriostatic or antibacterial effects [16][17][18][19][20][21][22]. These systems are anatase-modified photoactive TiO2 coatings and sol-gel coatings with colloidal metals or metal compounds embedded in them, such as silver, silver salt, copper compound, zinc or quaternary ammonium salt [18], so sol-gel technology can be applied to textiles to develop various functional finishes with antibacterial [23][24][25][26][27][28][29][30][31][32], water repellent [33][34][35][36][37][38], superhydrophobic [39][40][41][42][43][44], oil/water separations [45][46][47][48][49][50][51][52][53], flame-retardant [54][55][56][57][58][59][60][61]…”
Section: Introductionmentioning
confidence: 99%