2020
DOI: 10.1109/tmi.2020.2965724
|View full text |Cite
|
Sign up to set email alerts
|

Superspeed Bolus Visualization for Vascular Magnetic Particle Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
22
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(23 citation statements)
references
References 33 publications
0
22
0
Order By: Relevance
“…For increasing velocities, temporal blurring will become more prominent, which might lead to an inaccuracy in bolus arrival time estimation and hence, a reduced accuracy in velocity quantification. Recently, Franke et al measured peak flow velocities up to 1.0 m/s exploiting pulsed tracer information 26 and Vogel et al showed images of boluses moving with up to 0.4 m/s in their traveling wave MPI scanner 27 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…For increasing velocities, temporal blurring will become more prominent, which might lead to an inaccuracy in bolus arrival time estimation and hence, a reduced accuracy in velocity quantification. Recently, Franke et al measured peak flow velocities up to 1.0 m/s exploiting pulsed tracer information 26 and Vogel et al showed images of boluses moving with up to 0.4 m/s in their traveling wave MPI scanner 27 .…”
Section: Discussionmentioning
confidence: 99%
“…As a result, the constraint by peak splitting is not valid anymore, and one could only observe the shifted peak. It has to be noted that the aforementioned bolus tracking techniques [22][23][24][25][26][27] use 3D FFP trajectories for image acquisitions, whereas 1D excitation is applied in the presented experiments. Since the repetition time of a 1D excitation scheme is considerably lower, according to Eq.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…An integrated hybrid system combining MPI and MRI will assure spatial co-registration accuracy. A MPI/MRI Hybrid imaging system has been realized successfully, yet only used for static images and 2D phantom measurements 39,40 .…”
Section: Discussionmentioning
confidence: 99%
“…MPI has shown to be a promising tool for a variety of medical application including vascular [6,7,8] and oncological applications [9]. In particular MPI shows great potential in the area of intervention imaging since one can use one tracer to visualize the vessel tree using a blood pool tracer [10,11] and at the same time track medical devices such as guide wires, catheters [12,13], and stents [14].…”
Section: Introductionmentioning
confidence: 99%