2018
DOI: 10.1097/icu.0000000000000458
|View full text |Cite
|
Sign up to set email alerts
|

Suprachoroidal shunts

Abstract: Renewed interest in the suprachoroidal space has led to the development of new biocompatible glaucoma implants. Ab interno devices are easily combined with cataract surgery and preserve conjunctiva for future incisional glaucoma surgery. Additional data regarding the long-term efficacy and late complications of suprachoroidal shunts are needed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…The iStent Supra (Glaukos Corporation) is a 4 mm ridged tube of heparin-coated polyethersulfone with a lumen of 160-170 μm and a curved design to follow the supraciliary contour. 219,220 There is one single-armed published study of this device which evaluated the simultaneous use of two iStents, one iStent Supra and travaprost in refractory glaucoma with some success. 220…”
Section: Istent Supramentioning
confidence: 99%
See 1 more Smart Citation
“…The iStent Supra (Glaukos Corporation) is a 4 mm ridged tube of heparin-coated polyethersulfone with a lumen of 160-170 μm and a curved design to follow the supraciliary contour. 219,220 There is one single-armed published study of this device which evaluated the simultaneous use of two iStents, one iStent Supra and travaprost in refractory glaucoma with some success. 220…”
Section: Istent Supramentioning
confidence: 99%
“…The unit consists of a semiconductor diode laser, a Xenon light source, a Helium-Neon aiming beam and a video camera with a 110 -160 field of view within a 18-20G endoscope. 219 The extent of the pars plicata that is treatable is 270 though one corneal incision, 360 via two corneal incisions and the pars plana can be treated as well (ECP plus) in a vitrectomised eye or combined with a vitrectomy.…”
Section: Endoscopic Laser Photocoagulationmentioning
confidence: 99%
“…31 In the future, it may be possible to modulate this healing response with the use of antifibrotic agents, drugeluting stents, and expansion of the suprachoroidal reservoir with ophthalmic viscosurgical devices. 103…”
Section: Suprachoroidal Migs Devicesmentioning
confidence: 99%
“…Various surgical techniques and modifications of the existing techniques in the field have been proposed in the literature, and different devices have been used in clinical practice, to date, to enhance AH outflow via this pathway. However, the surgical outcomes of these techniques and devices are unpredictable [ 11 , 12 , 13 , 14 , 15 , 16 ]. In most of these techniques, performing surgical cyclodialysis is mandatory.…”
Section: Introductionmentioning
confidence: 99%