Oceans 2009 2009
DOI: 10.23919/oceans.2009.5422420
|View full text |Cite
|
Sign up to set email alerts
|

Sustained, autonomous coastal nutrient observations aboard moorings and vertical profilers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Table 1 indicates the figures of merit of the analyzer following our analytical improvements and compares the performance with other portable on-site analyzers reported in the literature and/or commercially available (WIZ [25], APNA [52], Hydrocycle PO4 [53], NAS3X [54], ANAIS [26], ALCHEMIST [23], NuLAB [55], and Lab on Chip (LOC) [56][57][58], as well as other UV spectral sensors for NO 3 − such as SUNA [59], OPUS [13,60], and SUV-6 [61]). The WIZ, APNA, NAS3X, ANAIS, and NuLAB devices are the only multi-nutrient analyzers reported to date.…”
Section: Analytical Performancementioning
confidence: 99%
“…Table 1 indicates the figures of merit of the analyzer following our analytical improvements and compares the performance with other portable on-site analyzers reported in the literature and/or commercially available (WIZ [25], APNA [52], Hydrocycle PO4 [53], NAS3X [54], ANAIS [26], ALCHEMIST [23], NuLAB [55], and Lab on Chip (LOC) [56][57][58], as well as other UV spectral sensors for NO 3 − such as SUNA [59], OPUS [13,60], and SUV-6 [61]). The WIZ, APNA, NAS3X, ANAIS, and NuLAB devices are the only multi-nutrient analyzers reported to date.…”
Section: Analytical Performancementioning
confidence: 99%
“…Wet chemistry analyzers have addressed sample introduction and pretreatment requirements using 10 μm screen filters, at times paired with copper wire for biofouling mitigation, which have proven to be effective with minimal maintenance in real-world deployments. 110,115 Instrument service to components, including cleaning of external films and particulate matter, and replacement of reagents, standards, wash solution, and filters have been reported to take place on a weekly or biweekly basis, especially in turbid and highly eutrophic environments. 100,110 Challenges for extending deployments of wet chemistry FDS include accounting for inevitable optical issues in turbid and complex sample matrices, where colloidal and suspended particulate matter can cause light scattering and refraction.…”
Section: And Limitationsmentioning
confidence: 99%
“…110,115 Instrument service to components, including cleaning of external films and particulate matter, and replacement of reagents, standards, wash solution, and filters have been reported to take place on a weekly or biweekly basis, especially in turbid and highly eutrophic environments. 100,110 Challenges for extending deployments of wet chemistry FDS include accounting for inevitable optical issues in turbid and complex sample matrices, where colloidal and suspended particulate matter can cause light scattering and refraction. Biofouling, another inexorable process in the natural environment, can significantly affect optical measurements in under 1 week's time and still requires a sustainable and effective solution.…”
Section: And Limitationsmentioning
confidence: 99%
See 2 more Smart Citations