2022
DOI: 10.1007/s10792-022-02579-w
|View full text |Cite
|
Sign up to set email alerts
|

Sutureless scleral fixation Carlevale IOL: a review on the novel designed lens

Abstract: Background: Complicated cataract surgery is the main cause of secondary lens implantation surgery. Several approaches have been introduced to face those circumstances. As it concerns scleral-fixated IOLs for the posterior chamber, many types of IOL can be implanted. The aim of article is to review the single piece sutureless scleral fixation Carlevale lens; Methods: Narrative review; Results: Several works described as safe the IOL implantation utilizing the handshake approach, without tactile manipulation, wh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 50 publications
1
5
0
Order By: Relevance
“…In general, the type and incidence of surgical complications encountered in our group were in line with those reported in the salient CIL literature [ 19 ]. The most common complications observed (transient IOP elevation and macular oedema in 8.3% of our patients) were each managed successfully with topical therapy.…”
Section: Discussionsupporting
confidence: 87%
“…In general, the type and incidence of surgical complications encountered in our group were in line with those reported in the salient CIL literature [ 19 ]. The most common complications observed (transient IOP elevation and macular oedema in 8.3% of our patients) were each managed successfully with topical therapy.…”
Section: Discussionsupporting
confidence: 87%
“…The post-operative evaluation of astigmatisms did not show differences from the pre-operative data. In this regard, a small corneal incision appears to induce less astigmatism than ACIOLs, iris claw lenses [ 26 , 36 , 52 ] or three-piece fixed-scleral IOLs [ 28 ].…”
Section: Discussionmentioning
confidence: 99%
“…Centration and tilting of the IOL were evaluated at the slit-lamp before and after pupil dilation. As already described in literature, the specific design of the IOL and the large dimensions of the optic plate make it especially stable and less prone to tilting [ 4 , 12 ]. Despite these satisfactory results, a precise evaluation of IOL tilting can only be performed using anterior segment OCT, a Scheimpflug camera, or ultrasound biomicroscopy, as described in literature [ 13 ].…”
Section: Discussionmentioning