2018
DOI: 10.1364/optica.5.000052
|View full text |Cite
|
Sign up to set email alerts
|

Swept source optical coherence tomography and tunable lens technology for comprehensive imaging and biometry of the whole eye

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
33
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 51 publications
(36 citation statements)
references
References 37 publications
0
33
0
3
Order By: Relevance
“…Among all intraocular distances, the lowest ICC was found in corneal thickness, which was due to the axial resolution of the SS-OCT system and limited digital resolution of OCT images (size of the pixel in z-direction, 5 lm), which was also observed in other reports. 18,19,34 Another interesting observation showed that the time intervals Dt v and Dt acc had higher reproducibility than the times of velocity/acceleration extrema, which may be attributed to the signal processing procedure of identifying those markers in corneal apex velocity/acceleration waveform.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Among all intraocular distances, the lowest ICC was found in corneal thickness, which was due to the axial resolution of the SS-OCT system and limited digital resolution of OCT images (size of the pixel in z-direction, 5 lm), which was also observed in other reports. 18,19,34 Another interesting observation showed that the time intervals Dt v and Dt acc had higher reproducibility than the times of velocity/acceleration extrema, which may be attributed to the signal processing procedure of identifying those markers in corneal apex velocity/acceleration waveform.…”
Section: Discussionmentioning
confidence: 99%
“…16,17 Apart from visualization of all eye components, the concept of full-eyelength SS-OCT imaging at 1060 nm was demonstrated in ocular biometry, showing high repeatability and reproducibility and very good correlation with other biometers. 18,19 This has led to the introduction of a new generation of optical biometers, such as IOL Master 700 (Carl Zeiss Meditec, Inc., Dublin, CA, USA), Argos (Movu, Inc., Santa Clara, CA, USA), or OA-2000 (Tomey, Nagoya, Japan), enabling improved measuring of cataract patients. [20][21][22] Prototype spectral-domain-OCT and SS-OCT anterior segment instruments integrated with air-puff indentation were used to assess biomechanics of the cornea for different IOP levels and to assess biomechanic effects of cross-linking procedures.…”
mentioning
confidence: 99%
“…Fruto de esta actividad investigadora ha sido la generación de distintos tejidos artificiales como córnea (14) , piel (15,16), mucosa oral (17), nervio periférico (18), paladar (19), cartílago (20), etc. utilizando distintos tipos celulares, biomateriales , procesos de biofabricación (21,22,23) y protocolos de control de calidad de los que se ha dado cuenta en publicaciones científicas (24, 25,26,27,28,29,30).…”
Section: Reto Investigadorunclassified
“…Se producen por liberación de sustancias constrictoras endógenas, pero también por uso de sustancias ilícitas vasospásticas, como cocaína o anfetaminas (25). Hasta un 46% de los pacientes con MINOCA responden a test de provocación de espasmo con ergonovina y acetilcolina (Ach).…”
Section: Figura 7 Mecanismo Del Desarrollo De Una Placa Arteriosclerunclassified
See 1 more Smart Citation