2008
DOI: 10.1109/tie.2008.918618
|View full text |Cite
|
Sign up to set email alerts
|

Switching Flow-Graph Modeling Technique for Three-Phase Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…This oscillation is natural and the control system can only fix its mean value forced by the set point. The simulation shows well as vanishing the delivered reactive power, the DC link voltage oscillation decreases with benefit for both the input and the grid current that exhibit a lower distortion as evident from Figures 16,17,18,19,and 20. It is worthwhile to remark that for avoiding overmodulation, the fault tolerant converter has a DC link voltage 25-30% greater than that of a traditional grid converter.…”
Section: Simulation Of a Grid Converter With Fault Tolerant Operationmentioning
confidence: 69%
See 1 more Smart Citation
“…This oscillation is natural and the control system can only fix its mean value forced by the set point. The simulation shows well as vanishing the delivered reactive power, the DC link voltage oscillation decreases with benefit for both the input and the grid current that exhibit a lower distortion as evident from Figures 16,17,18,19,and 20. It is worthwhile to remark that for avoiding overmodulation, the fault tolerant converter has a DC link voltage 25-30% greater than that of a traditional grid converter.…”
Section: Simulation Of a Grid Converter With Fault Tolerant Operationmentioning
confidence: 69%
“…Finally, Section 7 summarizes the conclusions. The current circulation on free-wheeling diodes is also considered as also illustrated in the references [19][20][21].…”
Section: Introductionmentioning
confidence: 99%
“…This proves that the model can handle open leg problems. Hereby, 2 of the flaws in the mentioned models [1][2][3][4] in the introduction have been solved. On the right side of the figure the currents (setpoints and actual current) are plotted.…”
Section: Figure 3: Examplesmentioning
confidence: 99%
“…When the combinations causing short circuits are excluded 27 combinations remain. However the models in [1][2][3][4] only consider 8 possible switching state combinations. Moreover, these switching state combinations differ from application to application.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation