2002
DOI: 10.1359/jbmr.2002.17.8.1372
|View full text |Cite
|
Sign up to set email alerts
|

Synchrotron Radiation Microtomography Allows the Analysis of Three-Dimensional Microarchitecture and Degree of Mineralization of Human Iliac Crest Biopsy Specimens: Effects of Etidronate Treatment

Abstract: Quantitative microcomputed tomography using synchrotron radiation (SR CT) was used to assess the effects of a sequential etidronate therapy on both three-dimensional (3D) microarchitecture and degree of mineralization of bone (DMB) in postmenopausal osteoporosis. Thirty-two iliac crest biopsy specimens were taken from 14 patients with osteoporosis (aged 64 ؎ 1.8 years) before (baseline) and after 1 year of etidronate treatment, and after 2 years of treatment for four of the patients. The samples were imaged at… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
85
0
1

Year Published

2005
2005
2018
2018

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 157 publications
(87 citation statements)
references
References 52 publications
1
85
0
1
Order By: Relevance
“…The meshes, being built of connected wires, had SMI values of 2.48-3.09 and were thus identified as mostly rod-like structures. From a practical point of view, the small size of the presented calibration phantom (13 mm diameter, 23 mm height) allows its use with commonly used microCT systems, which can be of commercial type, custom made (Rossi et al, 2002) or based on synchrotron sources (Nuzzo et al, 2002). Moreover, considering the thin structures contained in it, embedding in PMMA makes the phantom easy to handle and preserves it over time.…”
Section: Discussionmentioning
confidence: 99%
“…The meshes, being built of connected wires, had SMI values of 2.48-3.09 and were thus identified as mostly rod-like structures. From a practical point of view, the small size of the presented calibration phantom (13 mm diameter, 23 mm height) allows its use with commonly used microCT systems, which can be of commercial type, custom made (Rossi et al, 2002) or based on synchrotron sources (Nuzzo et al, 2002). Moreover, considering the thin structures contained in it, embedding in PMMA makes the phantom easy to handle and preserves it over time.…”
Section: Discussionmentioning
confidence: 99%
“…Parameters similar to those used in histomorphometry were computed using a 3D version of the mean intercept length (MIL) method [25,44]. For random directions in 3D space, the number of intercepts of a set of parallel test lines with the bone structure were computed and normalized by the total length of test lines.…”
Section: D Morphometric Analysismentioning
confidence: 99%
“…Despite these significant relationships, it has not been proven that the best estimation of cancellous bone mechanical properties from density measurements is provided by adding 2D structural parameters. Furthermore, the limitation of 2D images to estimate the 3D architecture of trabecular networks has been shown in several works [21][22][23][24][25].…”
Section: Introductionmentioning
confidence: 99%
“…L'utilisation du rayonnement synchrotron nécessite une infrastructure lourde qui existe en France sur deux sites : le european synchrotron radiation facility (ESRF) à Grenoble et le synchrotron Soleil à Saint-Aubin. Cette méthode de recherche est utilisée pour valider les autres méthodes d'investigation, et a déjà été utilisée pour explorer l'os humain [17] et les conséquences des traitements thérapeutiques [18]. dits apparents et ne permettent d'analyser que la texture.…”
Section: Les Techniques D'imagerie De La Structure Osseuseunclassified