2019
DOI: 10.1016/j.dyepig.2019.04.028
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis, spectroscopic characteristics, dyeing performance and TD-DFT study of quinolone based red emitting acid azo dyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 48 publications
(18 citation statements)
references
References 59 publications
1
17
0
Order By: Relevance
“…The results obtained in the waste characterization by FTIR after both processes showed the transformation of complex functional groups into simpler ones. Aromatic functional groups be transformed to the CH 3 group in the range of 1023-1093 cm −1 in Terasil Blue dye and 2850-3000 cm −1 in Erionyl Blue dye [46][47][48], and the decrement of toxic-type azo groups in the range of 1634 cm −1 [46,49], contributing to mineralization.…”
Section: Discussion Of the Resultsmentioning
confidence: 99%
“…The results obtained in the waste characterization by FTIR after both processes showed the transformation of complex functional groups into simpler ones. Aromatic functional groups be transformed to the CH 3 group in the range of 1023-1093 cm −1 in Terasil Blue dye and 2850-3000 cm −1 in Erionyl Blue dye [46][47][48], and the decrement of toxic-type azo groups in the range of 1634 cm −1 [46,49], contributing to mineralization.…”
Section: Discussion Of the Resultsmentioning
confidence: 99%
“…All statistical analysis were reported significantly (p< 0.05) with standard deviation. The limit of detection (LOD) and limit of quantification (LOQ) were determined by the average of standard deviation of the calibration curves by created via Zoner Photo Studio 17 program in terms of 3 times and 10 times of rate of 'slope / standard deviation' obtained from the calibration graphs of color line areas of all drugfood supplement interactions respectively in which the smallest pixel color depth parameters (with CIELAB (L*, a*, b*, h°, K / S) color measurement method 47 ) of rope printing images on TLC plates painted with textile dyes taken with the help of smartphone. Colour intensity values may be transformed into a pseudo absorbance value and then plotted against concentration to obtain linearized plots.…”
Section: Methodsmentioning
confidence: 99%
“…So, ω (electrophilicity index) was utilized. Parr et al defined the electrophilicity-index as the measurement of tendency of the group to absorb electrons and is mathematically expressed as [77,78]:…”
Section: Electrophilicity Indexmentioning
confidence: 99%