2019
DOI: 10.1016/j.actbio.2019.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Systematic comparison of methods for determining the in vivo biodistribution of porous nanostructured injectable inorganic particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 61 publications
0
9
0
Order By: Relevance
“…This ex vivo study revealed similar accumulation between lung and liver tissues, followed by spleen and kidneys, in contrast to data collected at similar time points via in vivo measurements that showed the highest accumulation occurs in lungs, followed by liver, kidneys, and then spleen. In a different study, Nizzero et al () also observed tissue attenuation effects in IVOI by directly comparing biodistribution of the fluorescent porous silica microdisks as estimated with IVIS Spectrum with the percent of injected dose (%ID) calculated by fluorescence measured in homogenized organs (Figure d). Notably, the two techniques differ in their ability to remove bias due to tissue attenuation of fluorescent signal.…”
Section: State‐of‐the‐art Imaging Modalities For Nps and Mabsmentioning
confidence: 96%
See 3 more Smart Citations
“…This ex vivo study revealed similar accumulation between lung and liver tissues, followed by spleen and kidneys, in contrast to data collected at similar time points via in vivo measurements that showed the highest accumulation occurs in lungs, followed by liver, kidneys, and then spleen. In a different study, Nizzero et al () also observed tissue attenuation effects in IVOI by directly comparing biodistribution of the fluorescent porous silica microdisks as estimated with IVIS Spectrum with the percent of injected dose (%ID) calculated by fluorescence measured in homogenized organs (Figure d). Notably, the two techniques differ in their ability to remove bias due to tissue attenuation of fluorescent signal.…”
Section: State‐of‐the‐art Imaging Modalities For Nps and Mabsmentioning
confidence: 96%
“…Results are shown after background subtraction. (Reproduced with permission from Nizzero et al, . Copyright 2019 Elsevier)…”
Section: State‐of‐the‐art Imaging Modalities For Nps and Mabsmentioning
confidence: 99%
See 2 more Smart Citations
“…OraEx4 or Alexa 594-LCFA-Ex4 (1 mg/kg) was administered to C57BL/6 mice (male, 5 to 6 weeks old) alone or in combination with phloretin (50 mg/kg) via oral gavage. Mice were euthanized, and major organs were harvested at 1, 2, 4, 8, and 12 hours after oral gavage for fluorescence imaging using an IVIS-200 in vivo imaging system (PerkinElmer) (46). Quantitative analysis of fluorescence in organs was performed using Living Image Software 4.2 (Caliper Life Sciences, Hopkinton USA).…”
Section: Sample Preparation For Temmentioning
confidence: 99%