2013
DOI: 10.1002/jmr.2326
|View full text |Cite
|
Sign up to set email alerts
|

Systematic, spatial imaging of large multimolecular assemblies and the emerging principles of supramolecular order in biological systems

Abstract: Understanding biological systems at the level of their relational (emergent) molecular properties in functional protein networks relies on imaging methods, able to spatially resolve a tissue or a cell as a giant, non-random, topologically defined collection of interacting supermolecules executing myriads of subcellular mechanisms. Here, the development and findings of parameter-unlimited functional super-resolution microscopy are described—a technology based on the fluorescence imaging cycler (IC) principle ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
32
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(32 citation statements)
references
References 69 publications
0
32
0
Order By: Relevance
“…The TIS technology used here, as noted in the Introduction, has advantages over other more recently introduced multiplexing methods [41,51,55,56]. In these systems the antibodies are tagged with Cy dyes and the fluorescence is quenched by exposing the sections to H 2 O 2 at pH > 10.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The TIS technology used here, as noted in the Introduction, has advantages over other more recently introduced multiplexing methods [41,51,55,56]. In these systems the antibodies are tagged with Cy dyes and the fluorescence is quenched by exposing the sections to H 2 O 2 at pH > 10.…”
Section: Discussionmentioning
confidence: 99%
“…We opted to use TIS for several reasons. Exposing the sections to H 2 O 2 at pH > 10 to quench the fluorescence [41,51,56,57], unlike photobleaching used in TIS, has been found to alter epitopes of some proteins and may decrease, eliminate, or enhance the fluorescence signal [41,57]. Unlike TIS the newer systems are yet to be automated and importantly lack the capabilities offered by the image processing software developed for use with TIS and referred to above.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These spatial blueprints, in turn, typically include so-called emergent systems [10], where emergence is understood as the process of complex pattern formation from more basic constituent parts [10]: large combinatorial molecular structures acquire, e.g. through the differential interplay of the numerous different protein classes, new properties in health and disease [10].…”
Section: Introductionmentioning
confidence: 99%