2016
DOI: 10.1007/s12647-016-0190-4
|View full text |Cite
|
Sign up to set email alerts
|

Systematic Uncertainty Evaluation of the Cesium Fountain Primary Frequency Standard at NPL India

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…Currently, the scale unit of International Atomic Time (TAI) is almost exclusively based on monthly frequency calibration reports by several fountain clocks serving as primary frequency standards (PFS) [2]. During the past five years, eleven primary caesium fountain clocks from eight different metrology institutes in Europe [3][4][5][6][7][8], the US [9][10][11] and Asia [12,13] contributed to TAI. One of these fountains additionally operated as a dual fountain, simultaneously using caesium and rubidium atoms [14], providing additional TAI calibrations with a secondary representation of the SI second.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, the scale unit of International Atomic Time (TAI) is almost exclusively based on monthly frequency calibration reports by several fountain clocks serving as primary frequency standards (PFS) [2]. During the past five years, eleven primary caesium fountain clocks from eight different metrology institutes in Europe [3][4][5][6][7][8], the US [9][10][11] and Asia [12,13] contributed to TAI. One of these fountains additionally operated as a dual fountain, simultaneously using caesium and rubidium atoms [14], providing additional TAI calibrations with a secondary representation of the SI second.…”
Section: Introductionmentioning
confidence: 99%
“…Among them, the largest contributions to the total uncertainty are collisional shift and microwave-power related frequency shift. CsF2 [20] CsF2 [95] FO2 [96] CsF2 [97] CsFO2 [21] F2 [98] NIM5 [99] CsF1 [100] FOC2 [97]…”
Section: Fountain Clock Evaluationsmentioning
confidence: 99%
“…Calibration of precision clocks, oscillators, GNSS receivers, stop watches, etc., is also provided. In addition, the NPL is working toward development of state-of-the-art ultramodern atomic clocks and dissemination techniques for improving time keeping and dissemination capabilities [86,87].…”
Section: Status Of Unit Of Time (Second)mentioning
confidence: 99%